Patton electronic 3087 Configure the IP address, Power-up indication, Connect a PC and log

Page 3

3.Insert the male plug of the AC power cord into an AC power outlet (mains) (100-240 V AC).

1.3 Power-up indication

The Power LED blinks as the ipRocketLink is powering up. When the Power LED stops blinking and remains lit, the ipRocketLink is ready for you to configure.

2.0 Configure the IP address

The ipRocketLink is shipped with a factory-configured IP address to the Ethernet LAN port (green outline). The IP address is 192.168.200.10/24. In most cases, you must change the address to be on the same subnet as your PC, as described in the procedures below. If you are not sure which IP address to use for your installa- tion, contact your network administrator.

2.1 Connect a PC and log in

1.Using the included combination RS-232/Ethernet cable and DB9-RJ45 adaptor, connect a PC’s serial port to the ipRocketLink’s Console port (see figure 1).

Power

Link

WAN

TD

RD

 

Sync

 

 

 

100M

Rx

 

 

Link

Tx

 

 

DTR

 

 

CTS

Ethernet

 

Serial

 

 

 

 

 

ipRocketLinkDevice

 

3086

Access

 

 

ModelIntegrated

Console

SHDSL

 

G.

- Normal

 

Modes

 

 

- 511E

 

Test

- 511

 

 

 

 

-

 

 

 

Local -

 

 

 

-

 

 

TM

Normal

 

ER

Remote

NS

 

 

 

 

 

Status

 

Connect to Console port

PC with

terminal emulator

Serial port

Figure 1. Connecting the ipRocketLink console port to the PC’s RS-232 serial port

2.Start a HyperTerminal (or similar terminal emulation program) session on the PC using the following set- tings:

9600 bps, 8 data bits, 1 stop bit, no parity, no flow control

3.Log into the ipRocketLink using the factory-default login username and password:

Login: superuser

Password: superuser

Login successful

2.2 Modify the IP address

1.Display current IP interface settings for the ipRocketLink Ethernet LAN port.

Model 3087 Quick Start Guide

3

Image 3
Contents Serial G.SHDSL Bridge/Router Power up the Bridge/Router Models with internal AC power supplyModels with external AC adaptor Modify the IP address Power-up indicationConfigure the IP address Connect a PC and logConnect to the local IP network Connecting the ipRocketLink to the local IP networkLog onto the GUI web management Connect to the G.SHDSL PortConnect the serial port Customer and Technical Support Additional InformationAppendix-Key factory default parameters Compliance InformationCompliance Radio and TV interference FCC Part EC Declaration of ConformityEG-Konformitätserklärung Industry Canada Notice FCC Part 68 Acta StatementCopyright statement

3087 specifications

The Patton Electronic 3087 is a state-of-the-art network interface device designed primarily for enterprises that require high-performance networking solutions. With its robust features and advanced technologies, the 3087 stands out as an essential component for facilitating seamless communication across diverse platforms.

One of the main features of the Patton 3087 is its versatility in supporting a variety of network topologies. It can function efficiently in both point-to-point and point-to-multipoint configurations, making it ideal for businesses that need to connect multiple locations or devices. This flexibility allows organizations to expand their networks without the need for extensive infrastructure changes.

The device is equipped with dual Ethernet ports, which support a range of data speeds, including Fast Ethernet and Gigabit, ensuring that it can handle high-volume data traffic efficiently. Additionally, the Patton 3087 supports Auto-MDIX, allowing it to automatically detect and configure itself for straight-through or crossover connections. This feature simplifies installation and reduces the chances of network errors.

In terms of technologies, the Patton 3087 utilizes advanced VoIP capabilities, enabling organizations to integrate voice communication through their data networks seamlessly. This is particularly beneficial for businesses looking to reduce communication costs while maintaining high-quality voice services. The device also supports various codecs, which can be customized based on specific requirements, ensuring optimal bandwidth usage.

Another key characteristic of the 3087 is its robust security features. The device includes built-in firewalls and encryption protocols, which help safeguard sensitive data as it traverses the network. This emphasis on security is critical for enterprises in regulatory environments where data protection is paramount.

Furthermore, the Patton 3087 is designed for easy management and monitoring. It features a user-friendly web interface, allowing network administrators to configure settings, monitor performance, and troubleshoot issues in real-time. This ease of management is complemented by support for SNMP (Simple Network Management Protocol), which facilitates network monitoring through third-party tools.

In summary, the Patton Electronic 3087 is a versatile and powerful networking solution tailored to meet the needs of modern enterprises. With its strong emphasis on flexibility, advanced VoIP capabilities, security features, and user-friendly management, it provides an ideal foundation for organizations looking to enhance their networking infrastructure and improve their communication efficiency. As technology continues to evolve, devices like the 3087 will be integral in helping businesses stay connected and competitive in the digital landscape.