Patton electronic 1140RC Specifications, Transmission Line Dual optical cable, Weight 2 oz

Page 10

1.Locate the lower of the two toggle switches on the front panel of the Model 1140RC and move it to the right. This will activate the V.52 BER test mode and transmit a “511” test pattern to the other unit. If any errors are present, the receiving modem’s red “Error” LED will blink sporadically. Note: For this independent test to function, the “511” switch on both Model 1140RCs must be turned on.

2.If the test indicates no errors are present, move the V.52 toggle switch to the left, thus activating the “511/E” test with periodic errors present. If the test is working properly, the receiving modem’s red “Error” LED will blinkregularly. A successful “511/E” test will confirm that the link is in place, and that the Model 1140RC’s built-in “511” generator and detector are working properly.

APPENDIX A

SPECIFICATIONS

Transmission Line: Dual optical cable

Transmission Mode: Asynchronous, half or full duplex, point-to-point

Interfaces: EIA RS-232, CCITT V.24

Data Rates: 0 - 57.6 Kbps

Distance: 2 miles over continuous fiber

RTS/CTS Delay: Switch-selectable: No delay, 7.0 mS, 53 mS

Receiver Sensitivity: -45 dBm

Coupled Power Output: -30 to -36 dBm

Optic Wavelength: 850 nm

LED Indicators: Power, TD, RD, RTS, CD, Test Mode, Error

Connectors: HD-26 female on RS-232 side; ST or SMA connectors on fiber side

Power Supply: 120/240V (switchable) on rack chassis

Temperature Range: 0-60°C(32-140°F)

Altitude: 0-15,000 feet

Humidity: Up to 95% non-condensing

Weight: 2 oz.

Dimensions: 0.95”W x 3.1”H x 5.4”L

17

18

Image 10
Contents User Manual Radio and TV Interference ServiceCE Notice Front Card Configuration FeaturesDescription Configuration Switch SET S1 S1 Summary TableRear Card Configuration Configuration Switch SET S2S2 Summary Table DTE Shield Pin 1 & Frgnd JB1 Rack Power SupplyHOW the Jumper Works Model 1000R16 Rack ChassisWiring UP the Model 1140RC Switching the Power Supply On and OffInstalling the Model 1140RC Into the Chassis 1 RS-232 ConnectionFiber Connections POWER-UPLED Status Monitors Local Analog Loopback LAL Using the V.52 BER Test IndependentlyTest Modes Remote Digital Loopback RDLWeight 2 oz SpecificationsTemperature Range 0-60C32-140F Transmission Line Dual optical cablePIN Configurations Appendix B Factory Replacement PartsPatton Model # Description Block Diagram