Kramer Electronics VS-88DTP user manual Machinename

Page 50

Identification commands

Command

Syntax

 

Response

Read machine name

NAME?

 

NAME

 

 

 

 

MACHINE_NAME

 

 

 

 

Reset machine name to

NAME-RST

 

NAME-RST

factory default*

 

 

MACHINE_FACTORY_NAME

 

 

 

 

RESULT

 

 

 

 

 

 

 

 

 

*Note: machine name not equal to model name. This name relevance for site viewer identification of specific machine or for network using (with DNS feature on).

MACHINE_NAME = Up to 14 Alfa-Numeric chars.

* Machine factory name = Model name + last 4 digits from serial number.

 

Network Setting Commands

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set IP Address

NET-IP

 

 

 

 

 

 

 

 

 

 

 

 

NET-IP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IP_ADDRESS

IP_ADDRESS

RESULT

 

 

 

 

NTIP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read IP Address

NET-IP?

 

NET-IP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IP_ADDRESS

 

 

 

 

NTIP?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read MAC Address

NET-MAC?

 

NET-MAC

MAC_ADDRESS

 

 

 

 

 

 

 

 

 

NTMC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set subnet mask

NET-MASK

SUBNET_MASK

 

 

 

 

NET-MASK

SUBNET_MASK

 

 

 

 

 

 

 

 

NTMSK

 

RESULT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read subnet mask

NET-MASK?

 

NET-MASK

 

 

 

 

 

 

 

 

 

 

 

 

SUBNET_MASK

 

 

 

 

NTMSK?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set gateway address

NET-GATE

 

 

 

 

 

 

 

 

 

 

 

NET-GATE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GATEWAY_ADDRESS

 

 

 

GATEWAY_ADDRESS

 

 

 

 

 

 

NTGT

 

RESULT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read subnet mask

NET-GATE?

 

NET-GATE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GATEWAY_ADDRESS

 

 

 

 

NTGT?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set DHCP mode

NET-DHCP

DHCP_MODE

 

 

 

NET-DHCP

DHCP_MODE

RESULT

 

 

 

 

 

NTDH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read subnet mask

NET-DHCP?

 

NET-DHCP

 

 

 

 

 

 

 

 

 

DHCP_MODE

 

 

 

 

NTDH?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

=

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DHCP_MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 – Don't use DHCP (Use IP set by factory or IP set command).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 – Try to use DHCP, if unavailable use IP as above.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Change protocol ethernet

ETH-PORT

 

PROTOCOL

,

PORT

 

 

ETH-PORT

PROTOCOL

 

,PORT

 

 

port

ETHP

 

RESULT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read protocol ethernet

ETH-PORT?

 

 

 

 

 

ETH-PORT

 

 

 

 

 

 

,

 

 

 

 

 

PROTOCOL

 

 

PROTOCOL

PORT

 

port

ETHP?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

= TCP / UDP

(transport layer protocol)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROTOCOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PORT = ethernet port to enter protocol 3000 commands.

1-65535 = User defined port

0 - reset port to factory default (50000 for UDP, 5000 for TCP)

46

VS-88DTP - Kramer Protocol

Image 50
Contents VS-88DTP Page Contents Figures Introduction Achieving the Best Performance Safety InstructionsGetting Started Recycling Kramer Products Overview Defining the VS-88DTP 8x8 DVI Twisted Pair Matrix Switcher This section defines the VS-88DTPVS 88DTP Overview Feature Function Using the IR Transmitter Installing the VS-88DTP in a Rack Connecting the VS-88DTP Connecting to the VS-88DTP via RS-232 Connecting the VS-88DTP 8x8 DVI Twisted Pair Matrix SwitcherTo set the RS-485 machine number using the DIP-switches Connecting a PC or Controller to the RS-485 PortSetting the RS-485 Machine Number To connect a device with a RS-485 port to the VS-88DTPSetting the RS-485 Bus Termination RS-485 DIP-switchesConnecting and Controlling Multiple VS-88DTP Devices To daisy-chain up to 16 VS-88DTP devicesSelect Properties Connecting the VS-88DTP via EthernetConnecting to the Ethernet Port Directly to a PC Local Area Connection Properties Window Connecting to the Ethernet Port via a Network Hub Routing Inputs to Outputs Disconnecting OutputsOperating the VS-88DTP To store a setup Storing and Recalling Setups in PresetsSwitching Between Protocol 2000 and Protocol To recall a setupAcquiring an Edid from Several Outputs to Several Inputs Acquiring the EdidAcquiring an Edid from a Single Output To acquire or change the Edid from a single outputAcquiring the Default Edid To reset to the default EDID, do the followingTo lock and unlock the front panel buttons Control Configuration via the Ethernet PortLocking and Unlocking the Front Panel Buttons Connecting to the VS-88DTP via your Browser Controlling the VS-88DTP Remotely via EthernetLoading page appears First Time Security Warning Main Switching Matrix Switching an Input to an OutputOperating in the Offline Mode To operate in the Offline modeStoring and Recalling Setups To store a switching configurationSelecting Preset Recalling a Preset in Offline Mode To lock the front panel buttons ConfigurationLocking the Front Panel Buttons To edit the IP-related settings Technical Specifications System RangeDefault Communication Parameters EdidDefault Edid KRMVS-88DTP Default Edid Updating the VS-88DTP Firmware Table of Ascii Codes for Serial Communication Protocol Hex Codes for Serial Communication Protocol OUTKramer Protocol Switching ProtocolsSwitching Protocols via the Front Panel Buttons Kramer Protocol14.2.2 Device Message Format Command TermsCommand ParametersCommand Chaining Entering CommandsCommand Forms Maximum String Length Backward SupportVID? LOCK-MODE Result Machinename Destination Instruction Instruction Codes for Protocol VS-88DTP Kramer Protocol Page Safety Warning

VS-88DTP specifications

Kramer Electronics VS-88DTP is a versatile and advanced 8x8 matrix switcher designed primarily for handling high-resolution video and audio signals. This device stands as a pivotal solution for various applications including video conferencing, presentations, and sophisticated broadcasting environments.

One of the standout features of the VS-88DTP is its ability to support 4K resolution at 60Hz, ensuring crystal-clear video quality that meets the demands of modern visual media. This capability is powered by its compatibility with the latest HDMI 2.0 and HDCP 2.2 standards, making it suitable for high-definition and ultra-high-definition content.

The VS-88DTP supports a variety of signal formats including HDMI, DTP (Digital Twisted Pair), and analog audio. The DTP technology utilizes twisted pair cabling, allowing for the transmission of video signals up to 70 meters at 4K resolution or up to 100 meters at lower resolutions. This flexibility ensures that integrators and installers can maintain clean and efficient cable management, reducing clutter while providing sufficient distance coverage.

One of the key technological advancements incorporated in the VS-88DTP is its built-in scaling and switching capabilities. This allows users to seamlessly switch between different input sources without interrupting the signal flow. The device features a user-friendly interface that can be operated through various control methods, including a front panel, an IR remote, or through a network using its built-in web interface or third-party control systems.

For audio management, the VS-88DTP includes stereo audio inputs and outputs, allowing for integration with audio systems easily. Additionally, it supports audio routing, which is crucial for environments requiring separate audio and video signal handling.

Reliability is another defining characteristic of the Kramer Electronics VS-88DTP. With its robust hardware design and built-in redundancy features, users can be assured of continuous operation even in demanding scenarios. Furthermore, the device is compatible with Kramer's extensive line of products, making it a scalable solution ideal for growing systems.

In conclusion, the Kramer Electronics VS-88DTP equips users with high-performance switching and scaling capabilities for both video and audio. Its range of features, advanced technologies, and comprehensive compatibility make it an excellent choice for professionals seeking reliable and high-quality signal distribution solutions in various media-rich environments.