Configures the OSD settings of the console used. The following sub menus will be listed:

Setting

OSD ACTIVATING HOTKEY

CHANNEL DISPLAY MODE

CHANNEL

DISPLAY

DURATION

CHANNEL

DISPLAY

POSITION

SCAN MODE

SCAN DURATION

PRIVATE MODE

RESTORE DEFAULT VALUES

MOUSE BUTTON SETUP

SET PASSWORD

Function

Can be selected for either pressing CONTROL key or SCROLL key twice

Selects the options how the channel display of the active port shows up on the monitor:

-Port number + name

-Port number only

-Name only

Selects how long the channel display is shown on the monitor:

-USER DEFINED: selectable 1-255 seconds

-ALWAYS ON

Select the position of the channel display on the monitor. Move the position with cursor keys and confirm by pressing ENTER.

Selects which ports are available for auto scan mode. (Only accessible ports – see F5 – are available for auto scan.)

The following selections are possible:

-ALL: all ports that are accessible according to F5 ACCESSIBLE

QVIEW: all ports marked QV in the OSD list

-POWERED ON: all ports powered on

-POWERED ON + QVIEW: all ports powered on and marked QV

-QVIEW + NAME: all ports marked QV that have been named

-NAME: all ports that have been named

Selects the dwell time per port in auto scan, selectable 1-255 seconds.

ENABLE: This port / computer can be accessed from this console only after being selected.

DISABLE: This port is available to all consoles.

The selection is made by pressing the ENTER key.

This function is used to undo all User changes and return the setup to the original factory default settings - except for the Names that were assigned to Ports, which are retained.

This function allows you to set the mouse for right or left handed operation. Use [Enter] to toggle between the two.

This function is for Users to set their passwords:

1.When you access this function, if you already have a password you must enter it in order to continue.

2.A screen appears that allows you to key in your new password. The password maybe up to 8 characters long, and can

consist of any combination of letters and numbers (A - Z, 0 - 9).

3.To modify or delete a previous password, use [Backspace] to delete the characters.

4.Key in the password, then press [Enter]. You are asked to key the password in again, in order to confirm that it is correct. Key in the new password again, and then press [Enter]. If the two entries match, the new password is accepted. If the entries do not match, you must start again from the beginning.

© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - FIRST EDITION (DEC 2001)

Image 13
Contents CPU Switch MultiMedia Packing List / Packliste Overview FeaturesHardware Requirements Console to Lindy CPU SwitchCables ConsoleFront View and Keys and Backside Connectors Single Stage Installation InstallationLED Lighting Pattern IndicationInstallation of cascaded Lindy CPU Switches Powering down and restarting Operating the CPU Switch MultiMediaHot-Plugging PC / Port selection OSD On-Screen-DisplayOSD Main Menu Information Navigation via OSD Menu OSD FunctionsOSD Display window of selected port / server Port NumberingChoice Function Keys F1 to F8Meaning F5 ADM SettingFunction Always on F6 SETTroubleshooting Factory Default SettingKeyboard and mouse not responding Technical Specs SpecificationFor Rack Mounting For StackingLieferumfang Deutsches BenutzerhandbuchBerblick Anschlusskabel Hardware-VoraussetzungenEIN/AUS-Schalter Eingang fü r Stromversorgung vom Netzteil Bedienelemente, Anschlü sseKonsolenanschlü sse Console 1 und Console Konsolenanschlü sse Console 3 und ConsoleBevor Sie beginnen Einfache Installation, bis zu 8 angeschlossene RechnerAnzeigemuster Fehlerbeschreibung Installation mit kaskadierten Lindy CPU Switches Abschalten und Neustart Arbeiten mit dem CPU Switch MultiMediaAnwahl der Rechner OSD On-Sreen-Display OSD Hauptmenuezeilen Navigation im OSD-Menu OSD FunktionenAnzeige des ausgewä hlten Rechners Port-NummerierungAuswahl Funktionstasten F1 bis F8Bedeutung F5 ADM F6 SET Default Einstellung ProblembehebungWerkseinstellungen / Lieferzustand Keine Funktion von Tastatur und/oder MausFunktion Technische SpezifikationenSpezifikation CE-Anmerkung Stapelelemente & 19 MontageGarantie StapelelementeUser @ 8 PC Lindy Art. Nr