Use the provided 2P terminal plug for signal wiring and plug into the PF+/- contacts.
Relay Output | Normal | PF+ and PF- contacts shorted |
Indication |
|
|
Alarm | PF+ and PF- contacts open | |
|
|
|
Alarm Events:
Input power failure
Specific fiber port link down (To specify the fiber ports, use the DIP SW located on bottom.)
| SW1 | ON | Enable broadcast storm protection |
|
|
|
|
|
| OFF | Disable broadcast storm protection |
|
|
|
|
| SW2 | ON | Enable FX port link down alarm |
|
|
|
|
|
| OFF | Disable FX port link alarm |
|
|
|
|
|
| ||
|
|
|
|
| SW1 | ON | Enable broadcast storm protection |
|
|
|
|
|
| OFF | Disable broadcast storm protection |
|
|
|
|
| SW2 | ON | Enable FX1 port link down alarm |
|
|
|
|
|
| OFF | Disable FX1 port link alarm |
|
|
|
|
| SW3 | ON | Enable FX2 port link down alarm |
|
|
|
|
|
| OFF | Disable FX2 port link alarm |
|
|
|
|
Note: Be sure the voltage applied on PF+/- contacts is within the specification of 30VDC/1A max. or 120VAC/0.5A max.
15/20