3.1Projector Web Control - Network Settings (continued)

 

 

 

Item

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

Wireless Setup

Configures the wireless LAN settings.

 

 

 

Mode

Select "AD-HOC" or "Infrastructure".

 

 

 

IP Configuration

Configures network settings.

 

 

 

 

DHCP ON

Enables DHCP.

 

 

 

 

 

DHCP OFF

Disables DHCP.

 

 

 

 

 

 

IP Address

Configures the IP address when DHCP is disabled.

 

 

 

Subnet Mask

Configures the subnet mask when DHCP is disabled.

 

 

 

Default

Configures the default gateway when DHCP is disabled.

 

 

 

Gateway

 

 

 

 

 

 

 

 

 

 

DNS Server Address

Configures the DNS server address.

 

 

 

 

 

 

Select a channel from “1” to “11” to use in the AD-HOC mode.

 

 

 

 

NOTE • Depending on the country where you are the

 

Ch

channels may vary. In addition, depending on the country

 

or region where you are, you may be required to use a

 

 

 

 

 

 

 

 

wireless network card that confirm to the standards in the

 

 

 

 

respective country or region.

 

 

 

 

 

 

 

 

 

 

Encryption

Select data encryption method.

 

 

 

 

 

 

Input the WEP key.

 

 

 

 

 

 

 

Either ASCII characters or hexadecimal numbers can be

 

 

 

 

used during WEP key input. However, you cannot use a

 

WEP Key

combination of both.The length of the key is defined as

 

follows according to the WEP and character formats.

 

 

 

 

 

Encryption

 

ASCII characters

HEX numbers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WEP 64bit

 

5 characters

10 characters

 

 

 

 

 

 

WEP 128bit

 

13 characters

26 characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input WPA Passphrase.

 

 

 

WPA Passphrase

Available number of input characters is 8 to 63. Only

 

alphabets, numbers and following symbols can be used.

 

 

 

 

 

 

 

 

!"#$%&'()*+,-./:;<=>?@ [\]^_`{}~ and space

 

 

 

 

Select an SSID from the list.

 

 

 

 

 

 

If you require to set your unique SSID, select [Custom], then

 

SSID

set your own SSID following the rules below.

 

Maximum number of input characters is 32.

 

 

 

 

 

 

 

 

Only alphabets, numbers and following symbols can be used.

 

 

 

 

!"#$%&'()*+,-./:;<=>?@[\]^_`{}~ and space.

(continued on next page)

 

 

 

 

 

 

20

Image 20
Contents Trademark acknowledgment FeaturesThank you for purchasing this product Contents Manual network connection setting Wireless LANConnection to the network Network Presentation Web ControlNetwork Bridge Function Other FunctionsSecurity precautions when using wireless LAN Do not USE Near the FollowingConnection to the network System requirementsRequired equipment preparation Hardware and software requirement for computerSystem requirements Manual network connection setting Wired LAN This section explains how to set it up manuallyNetwork settings Equipments connectionManual network connection setting Wired LAN About IP address Setting manually Setting automaticallyInternet Option setting Manual network connection setting Wireless LAN Preparation for wireless LAN connectionWireless Manual network connection setting Wireless LANWireless LAN connection set up About IP address Manual network connection setting Wireless LAN Network Presentation Web Control Logon User name Password Administrator BlankProjector Web Control Projector Web Control Network InformationLAN DhcpDisplays and configures network settings AMX D.DDhcp OFF Projector Web Control Network SettingsDhcp on Crestron e-Control Wired SetupOther Setup Port Settings Displays and configures communication port settingsProjector Web Control Port Settings Click the Apply button to save the settingsSend Test Mail Mail SettingsDisplays and configures e-mail addressing settings Alert Settings Displays and configures failure & alert settingsAlarm Time Only Lamp Time Alarm and Filter Time AlarmExcept Cold Start and Authentication Failure Snmp TrapSchedule Settings Displays and configures schedule settingsMessenger Description ScheduleDate Month/Day Projector Web Control Schedule Settings First, 2, 3, 4, Last Date/Time SettingsDisplays and configures the date and time settings Projector Web Control Date/Time Settings Time differenceSntp Sntp Server AddressSecurity Settings SnmpProjector Control Projector Web Control Projector Control Setup Auto Keystone Auto ECO ModeECO Mode InstallationAudio Volume MIC VolumeSpeaker Audio SourceDirect Power on Auto Power OFFOption Auto Search MY BUTTON-1Service Remote Control Displays the settings and status of the projector Projector StatusDescription Restart Network RestartRestarts the projector’s network connection Window Crestron e-ControlClicking the corresponding tab at the top right Crestron e-Control Main windowSources List Selects input from LAN portCrestron e-Control- Main window Projector Tools windowCrestron Control Projector Configures the network settings of the projector User PasswordAdmin Password Crestron e-Control- Tools windowInfo window Projector InformationHelp Desk window Emergency Alert My Image Function OPTION menu in the Operating GuideMessenger Function LAN port USB Type a port Control port Connecting devicesNetwork Bridge Function Communication setup Communication portControl port ConditionTransmission method HALF-DUPLEXTransmission method FULL-DUPLEXMail Alerts Mail Settings &24Other Functions Mail Alerts Projector Management using Snmp Snmp Settings &23Event Scheduling Schedule Settings &27 Event SchedulingDate/Time Settings &30 Communication Port Command Control via the NetworkFollowing two ports are assigned for the command control Command Control via the Network Command Format Reply Error codeHeader Data length RS-232Ccommand Check Sum Connection TCP #9715Reply Data format Authentication Automatic Connection BreakCrestron RoomView Troubleshooting Problem Likely Cause Things to CheckSpecifications Warranty and after-sales service

8929W, 8930, 8755N, 8931W, 8937 specifications

Dukane is a significant player in the field of ultrasonic plastic welding, offering a range of models designed for various industrial applications. Among its notable products are the Dukane 8937, 8931W, 8755N, 8930, and 8929W. Each of these models comes with unique features, technologies, and characteristics that set them apart in the market.

The Dukane 8937 is renowned for its robust construction and reliability. It incorporates advanced ultrasonic technology, which enables precise welding of thermoplastic materials. One of its standout features is the ability to deliver high power output, which facilitates quick and efficient welding processes, significantly reducing cycle times. The 8937 is also equipped with an intuitive user interface, allowing operators to easily program and monitor the welding parameters.

Next in the lineup is the Dukane 8931W, which boasts wireless capabilities. This feature allows for remote operation and monitoring, enhancing flexibility on the factory floor. The 8931W incorporates smart technology that enables real-time data collection and analysis, ensuring optimal welding conditions and increasing production efficiency. Its ergonomic design also makes it user-friendly, promoting better operator comfort during prolonged use.

The Dukane 8755N is a compact and lightweight model ideal for tight spaces. It is engineered with durability in mind, making it suitable for high-demand environments. This model features a high-frequency ultrasonic generator that provides consistent power output, ensuring high-quality welds with minimal defects. Additionally, the 8755N supports a range of ultrasonic tooling options, allowing for versatility in various applications.

The Dukane 8930 is designed for applications requiring high precision. With its advanced control systems, this model ensures repeatability and consistency in each weld. The 8930’s integrated monitoring systems provide real-time feedback, which helps in adjusting parameters on the fly and maintaining high-quality standards throughout the production process.

Lastly, the Dukane 8929W combines advanced features with a user-friendly interface. It supports a wide range of materials, making it adaptable to different manufacturing needs. The model includes an automated calibration feature, optimizing the welding process by adjusting settings according to material thickness and type.

In summary, the Dukane 8937, 8931W, 8755N, 8930, and 8929W each present exceptional characteristics and technologies that cater to a variety of industrial requirements. With their focus on efficiency, reliability, and precision, these models contribute significantly to the evolution of automated manufacturing processes, ensuring high-quality production standards in the plastics industry.