Dukane 28A8941, 8941A user manual Troubleshooting, Indicators Message

Page 23

TROUBLESHOOTING (continued)

Indicators Message

The POWER indicator, LAMP indicator, and TEMP indicator are lit and blank as follows. Take the appropriate measures.

Table 10. Indicators Message

POWER

LAMP

TEMP

Contents

indicator

indicator

indicator

 

 

 

 

 

Lights

Turns off

Turns off

The Standby mode has been set.

orange

 

 

 

 

 

 

 

Blinks

Turns off

Turns off

Warming up. Please wait.

green

 

 

 

 

 

 

 

Lights

Turns off

Turns off

ON. Normal operation possible.

green

 

 

 

 

 

 

 

Blinks

Turns off

Turns off

Cooling. Please wait.

orange

 

 

 

 

 

 

 

 

 

 

Lamp is not lit.

 

 

 

The interior of the equipment may be too hot. Switch

 

Lights

 

power OFF, wait 20 minutes until the equipment cools,

Lights red

Turns off

and check whether the ventilation openings are blocked,

red

 

 

whether the air filter is dirty, or whether the ambient

 

 

 

 

 

 

temperature exceeds 35 °C. And switch power ON

 

 

 

again. Replace the lamp if the same problem occurs.

 

 

 

 

 

 

 

Lamp or lamp cover is not found, or hasn’t been fitted in

 

 

 

correctly.

Lights red

Blinks

Turns off

Switch power OFF, and wait for 45 minutes until the

 

red

 

equipment cools. Check fitting of the lamp and lamp

 

 

 

cover, and switch power ON again. Contact your dealer if

 

 

 

the same problem occurs again.

 

 

 

 

 

 

 

The cooling fan is not operating.

 

 

Blinks

Switch power OFF, and wait for 20 minutes until the

Lights red

Turns off

equipment cools. Check for foreign matters in the fan,

red

 

 

and switch power ON again. Contact your dealer if the

 

 

 

 

 

 

same problem occurs again.

 

 

 

 

 

 

 

The interior of the equipment is too hot.

 

 

 

Switch power OFF, and wait for 20 minutes until the

 

 

Lights

equipment cools. Check whether the ventilation openings

Lights red

Turns off

are blocked, whether the air filter is dirty, or whether the

red

 

 

ambient temperature exceeds 35 °C. Then switch power

 

 

 

 

 

 

ON again. Contact your dealer if the same problem

 

 

 

occurs again.

 

 

 

 

NOTE When the internal temperature becomes excessive power is switched OFF automatically for safety reasons, and the indicator is extinguished. Set the power switch to [O] and wait for 20 minutes until the equipment has cooled sufficiently.

ENGLISH

ENGLISH-21

Image 23
Contents 28A8941/8941A Page Contents Before USE FeaturesContents of package Part Names Before USEENGLISH-4 Loading the Batteries Installation Reference InstallationInstallation of the Projector and Screen Angle AdjustmentCabling InstallationCabling Plug & Play Power ConnectionExample of System Setup Standby Power onPower OFF OperationsBasic Operation Description OperationsBasic Operation Menu Display Start/Stop Press the Menu button Select Mode of P.IN P. Display Press the PinP buttonSet / Clear Keystone Mode Press the Keystone button Normal menu Single menuSetup Menu Setup MenuBlack Input MenuInput Menu Description RGBMirror Image MenuImage Menu Description MyScreenOperation Start/Stop Press Options MenuOptions Menu Select Menu Background Color Select withNo Signal Menu No Signal MenuLamp Life MaintenanceLamp Replacing the Lamp MaintenanceResetting the Lamp Timer Air Filters Other MaintenanceOSD Message TroubleshootingMessage Contents OSD MessageIndicator TroubleshootingIndicators Message Indicators MessageSymptom Possible cause Remedy SymptomSymptom Specifications SpecificationsWarranty and AFTER-SERVICE Technical Dimension DiagramSignal Connector Pin Assignment Technical Example of computer signalInitial set signals PS/2 Mouse Connection to the Mouse ControlPS/2, ADB or Serial Mouse USB MouseSerial Mouse ADB MouseProtocol Communications settingCommand data RS-232C communicationIncreasing the projector setting value Increment command Requesting projector status Get commandChanging the projector settings Set command Using the projector default settings Reset CommandCRC Be EF BA D2 Be EF FD D3 Be EF Ntsc PAL RGB Be EF For the Customers in Canada Pour les utilisateurs au Canada Regulatory NoticesFCC Statement Warning Dukane Corporation Page Audio Visual Products

28A8941, 8941A specifications

The Dukane 8941A and 28A8941 are advanced ultrasonic welding systems designed for high-performance applications across a variety of industries. These machines exemplify the cutting-edge technology that Dukane has to offer, making them vital tools for manufacturers seeking reliable and efficient joining solutions.

One of the standout features of the Dukane 8941A and 28A8941 is their ultrasonic technology, which utilizes high-frequency vibration to create localized heating at the interface of materials. This process allows for quick and efficient joining of thermoplastics, metals, and other materials with minimal pressure and without the need for adhesives or fasteners. The systems operate at frequencies typically around 20 kHz, which optimizes the welding process by ensuring fast cycle times and consistent, repeatable results.

The systems come equipped with an intuitive user interface, making it easy for operators to set parameters and monitor the welding process in real-time. This user-friendly design helps minimize the learning curve and allows for efficient operation in various production environments. Additionally, the machines provide comprehensive data logging capabilities, enabling users to track performance metrics and maintain quality control with ease.

Another significant characteristic of the Dukane 8941A and 28A8941 is their adaptability. These ultrasonic welding systems can be tailored to accommodate different applications, whether the need is for spot welding, staking, or cutting. The machines can also handle a wide range of material thicknesses, ensuring versatility in manufacturing processes.

In terms of durability and maintenance, Dukane has designed these systems with robust components that are engineered for prolonged use. Regular maintenance is made simple, allowing manufacturers to keep their equipment running smoothly with minimal downtime.

Moreover, the Dukane 8941A and 28A8941 incorporate advanced safety features, ensuring that operators can work without risk. The systems include emergency stop buttons, overload protection, and built-in fail-safes, prioritizing both performance and operator security.

In summary, the Dukane 8941A and 28A8941 ultrasonic welding systems represent a pinnacle of modern manufacturing technology. With their efficient ultrasonic technology, user-friendly interfaces, adaptability to various applications, durability, and integrated safety features, these machines stand out as premier solutions for businesses looking to enhance their production capabilities.