TROUBLESHOOTING (continued)

Indicators Message

The POWER indicator, LAMP indicator, and TEMP indicator are lit and blank as follows. Take the appropriate measures.

Table 10. Indicators Message

POWER

LAMP

TEMP

Contents

indicator

indicator

indicator

 

 

 

 

 

Lights

Turns off

Turns off

The Standby mode has been set.

orange

 

 

 

 

 

 

 

Blinks

Turns off

Turns off

Warming up. Please wait.

green

 

 

 

 

 

 

 

Lights

Turns off

Turns off

ON. Normal operation possible.

green

 

 

 

 

 

 

 

Blinks

Turns off

Turns off

Cooling. Please wait.

orange

 

 

 

 

 

 

 

 

 

 

Lamp is not lit.

 

 

 

The interior of the equipment may be too hot. Switch

 

Lights

 

power OFF, wait 20 minutes until the equipment cools,

Lights red

Turns off

and check whether the ventilation openings are blocked,

red

 

 

whether the air filter is dirty, or whether the ambient

 

 

 

 

 

 

temperature exceeds 35 °C. And switch power ON

 

 

 

again. Replace the lamp if the same problem occurs.

 

 

 

 

 

 

 

Lamp or lamp cover is not found, or hasn’t been fitted in

 

 

 

correctly.

Lights red

Blinks

Turns off

Switch power OFF, and wait for 45 minutes until the

 

red

 

equipment cools. Check fitting of the lamp and lamp

 

 

 

cover, and switch power ON again. Contact your dealer if

 

 

 

the same problem occurs again.

 

 

 

 

 

 

 

The cooling fan is not operating.

 

 

Blinks

Switch power OFF, and wait for 20 minutes until the

Lights red

Turns off

equipment cools. Check for foreign matters in the fan,

red

 

 

and switch power ON again. Contact your dealer if the

 

 

 

 

 

 

same problem occurs again.

 

 

 

 

NOTE *1) When the internal temperature becomes excessive power is switched OFF automatically for safety reasons, and the indicator is extinguished. Set the power switch to [O] and wait for 20 minutes until the equipment has cooled sufficiently.

ENGLISH

ENGLISH-21

Image 31
Contents 28A8909 Page Page Page Page Page Page Page Page Page Contents Contents of package FeaturesBefore USE Terminal Part NamesControl Panel Front/Right View Rear/Left ViewENGLISH-4 Loading the Batteries Installation Reference InstallationInstallation of the Projector and Screen Angle AdjustmentCabling CablingExample of system setup Power ConnectionPlug & Play Equipment is used safely Power onPower OFF OperationsBasic Operation Image Position Adjustment PressSet Magnify Mode Press the Magnify Adjust Magnification Press the MagnifyNormal menu Single menu Select Mode of P.IN P. Display Press the PinP buttonMenu Display Start/Stop Press the Menu button Setup Menu Setup MenuInput Menu Description Automatic Adjustment at RGB Input Select the Execute withAutomatic Adjustment at Video Input Select the Execute with Input MenuImage Menu Image MenuOptions Menu Description Options MenuNo Signal Menu No Signal MenuLamp Life MaintenanceLamp Lamp Replacing the Lamp Resetting the Lamp TimerCleaning the Lens Air Filter MaintenanceOther Maintenance Maintenance Inside the EquipmentOSD Messages TroubleshootingMessage Contents OSD MessageIndicators Message Indicators MessageIndicator Symptom SymptomSymptom Possible cause Remedy Specifications SpecificationsWarranty and AFTER-SERVICE Signal Connector Pin Assignment Dimension DiagramTechnical Resolution FH kHz FV Hz Rating Signal mode Display Example of computer signalTechnical Initial set signalsPS/2 Mouse Connection to the Mouse ControlPS/2, ADB or Serial Mouse USB MouseSerial Mouse ADB MouseProtocol Communications settingCommand data RS-232C communicationIncreasing the projector setting value Increment command Requesting projector status Get commandChanging the projector settings Set command Using the projector default settings Reset CommandCRC Be EF BA D2 Be EF FD D3 Be EF Ntsc PAL RGB Be EF FCC Statement Warning Regulatory NoticesFor the Customers in Canada Pour les utilisateurs au Canada Page Legal Information Audio Visual Products