PJLink command (continued)
Commands | Control Description | Parameter or Response | |
|
|
| |
|
| 1st byte: Refers to Fan error; one of 0 to 2 | |
|
| 2nd byte: Refers to Lamp error; one of 0 to 2 | |
|
| 3rd byte: Refers to Temptrature error; one of 0 to | |
|
| 2 | |
|
| 4th byte: Refers to Cover error; one of 0 to 2 | |
ERST ? | Error Status inquiry | 5th byte: Refers to Filter error; one of 0 to 2 | |
|
| 6th byte: Refers to Other error; one of 0 to 2 | |
|
|
| |
|
| The mearning of 0 to 2 is as given below | |
|
| 0 = Error is not detected; 1 = Warning; 2 = | |
|
| Error | |
LAMP ? | Lamp Status inquiry | 1st number (digits 1 to 5): Lamp Time | |
2nd number : 0 = Lamp off, 1 = Lamp on | |||
|
| ||
INST ? | Input Source List inquiry | 11 12 22 23 31 41 51 52 | |
NAME ? | Projector Name inquiry | Responds with the name set in "PROJECTOR | |
NAME" of "NETWORK" | |||
|
| ||
INF1 ? | Manufucturer's Name | HITACHI | |
inquiry | |||
|
| ||
INF2 ? | Model Name inquiry | ||
INFO ? | Other Information inquiry | Responds with the factory information and so | |
on | |||
CLSS ? | Class Information inquiry | 1 |
NOTE • The password used in PJLinkTM is the same as the password set in the Web Brouwser Comtrol. To use PJLinkTM without authentication, do not set any password in Web Browser Control.
•For specifications of PJLinkTM, see the web site of the Japan Business Machine and Information System Industries Association.
URL: http://pjlink.jbmia.or.jp/
DUKANE CORP AV SERVICE DEPT
2900 Dukane Drive
St Charles, IL 60174
32