5) SW2 is used to enable or disable the converter.

For positive logic module, When SW2 is put in the ON position, the converter is ON and when SW2 is put in the OFF position, the converter is OFF.

For negative logic module, When SW2 is put in the OFF position, the converter is ON, and when SW2 is put in the ON position, the converter is OFF.

6) SW3 is used for the Output Voltage Set-Point Adjustment Range. By an external voltage source:

If the converter requires a trim up, set the SW3_1 to ON position.

If the converter requires a trim down, set the SW3_2 to ON position. By an external resistor:

If the converter requires a trim up to Vo,set, set the SW3_8 to ON position. If the converter requires a margin trim down, set the SW3_3 to ON position. If the converter requires a margin trim up, set the SW3_4 to ON position.

Please refer to the SW3 Function table.

SW3 Function table

 

Subdivide switch No.

Function

 

SW3_1

Voltage trim up

 

SW3_2

Voltage trim down

 

SW3_3

Resistor margin trim down

 

SW3_4

Resistor margin trim up

 

SW3_8

Resistor trim up

Note:

 

1.

The subdivide switch of SW3_1~4 must not be ON at the same time.

2.

For the SW3_5~7 use at NPA series, must set to OFF position.

7.2 Initial Power Up

1) Turn the power supply ON, set the current limit on DC source (refer to specification of either converter) and increase the input voltage (use DVM2 to monitor the input voltage) until it reaches the desired value.

2) Set the switch SW2 to power module ON.

3) The converter is now operating, which can be verified by observing the DVM3 (appropriate value for the nominal output voltage) and channel 2 of the oscilloscope (appropriate value for the nominal output voltage).

4) Set the switch SW2 to power module OFF.

5

Image 5
Contents Relevant Documentation Delphi DNS Series of SIP type POL convertersPurpose Equipment Set-Up and Description Equipment RequiredThermal Management of the Converter Test Set-Up Tests PerformedSW3 Function table Initial Power UpNo Load Input Current Test Tests and EvaluationTest Output Ripple Output Characteristics Line RegulationLoad Regulation 10500 Vtrim = 0.7 − 0.1698 ⋅ Vout − For DNS04xx seriesVoltage Margining For DNS12xx seriesDetailed Description Sequential Implementation Voltage TrackingRatio-Metric Implementation PS1 PS2PS1=5V VrefSimultaneous Implementation PS1=5V PS2=3.3VVref Definition Voset,ps2 Test Dynamic Characteristics Output Voltage DeviationTurn-On Response Time Test Turn on the module by using the external switchTest Turn on the module by using the Enable on/off Thermal Characteristic Efficiency Appendix A- Evaluation Board Schematic Warranty