Absolute Maximum Ratings

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Storage Temperature

Ts

-40

 

85

ºC

 

Supply Voltage

VCC

0

 

5

V

 

Recommended Operating Conditions

 

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

 

Case Operating Temperature

TC

-5

 

+70

ºC

1

 

Supply Voltage

VCC

3.135

 

3.465

V

 

 

Relative Humidity (non condensation)

-

5

 

85

%

 

Note 1: See order information

 

 

 

 

 

 

Electrical Characteristics (VCC=3.135V to 3.465V)

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Total Supply Current

ICCT

 

180

300

mA

 

Transmitter

 

 

 

 

 

 

Transmitter Differential Input Voltage

VDT

0.5

 

2.4

V

1

Transmitter Disable Input-High

VDISH

2

 

VCC+0.3

V

 

Transmitter Disable Input-Low

VDISL

0

 

0.8

V

 

Transmitter Fault Pull up Resistor

RTX_FAULT

4.7

 

10

kΩ

2

Transmitter Fault Output-High

VTXFH

2

 

VCC+0.3

V

 

Transmitter Fault Output-Low

VTXFL

0

 

0.8

V

 

Receiver

 

 

 

 

 

 

Receiver Differential Output Voltage

VDR

0.35

1

2

V

3

Receiver LOS Load

RRXLOS

4.7

 

10

kΩ

2

LOS Output Voltage-High

VLOSH

2

 

VCC+0.3

V

 

LOS Output Voltage-Low

VLOSL

0

 

0.8

V

 

Output Data Rise/Fall Time

tr/ tf

 

 

2.5

nsec

4

Notes:

1.Internally AC coupled and terminated to 100 Ohm differential load.

2.Pull up to VCC on host Board

3.Internally AC coupled, but requires a 100 Ohm differential termination at or internal to Serializer/ Deserializer.

4.These are 20%~80% values

2

Jan., 2008

 

Rev. 0D

DELTA ELECTRONICS, INC.

www.deltaww.com

Image 2
Contents Performance DescriptionApplications Recommended Operating Conditions Electrical Characteristics VCC=3.135V toAbsolute Maximum Ratings PA-PD Optical CharacteristicsMask of the eye diagram for the optical transmit signal MOD-DEF2 Open PLD / PAL Package Outline Drawing for Metal Housing with Bail de-latch SFP timing parameters for SFP management TxdisableTxfault SFP timing parameters Address Regulatory Compliance EMIOrdering information for SFP modules Related Products