SFP timing parameters for SFP management
Parameter |
| Symbol | Min. | Max. | Unit |
|
| Unit Conditions | |||
TX_DISABLE Assert |
|
|
|
| Time | from | rising edge | of TX_DISABLE to | |||
t_off |
| 10 | µsec | when the optical output falls below 10% of | |||||||
time |
|
|
|
| |||||||
|
|
|
|
|
|
| nominal |
|
| ||
|
|
|
|
|
|
|
|
|
| ||
TX_DISABLE |
|
|
|
|
| Time | from | falling edge | of TX_DISABLE to | ||
| t_on |
| 1 | msec | when | the | modulated | optical output rises | |||
Negate time |
|
| |||||||||
|
|
|
|
| above 90% of nominal |
| |||||
|
|
|
|
|
|
|
|
| |||
Time | to | initialize, |
|
|
|
| From power on or negation of TX_Fault using | ||||
including | reset | of | t_init |
| 300 | msec | |||||
| TX Disable. |
|
| ||||||||
TX_FAULT |
|
|
|
|
|
|
|
|
|
| |
TX | Fault | Assert | t_fault |
| 100 | µsec | Time from fault to TX fault on. | ||||
Time |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| |
TX_DISABLE | to | t_rest | 10 |
| µsec | Time TX Disable must be held high to reset | |||||
reset |
|
|
|
| TX_Fault |
|
| ||||
LOS Assert Time |
| t_loss_on |
| 100 | µsec | Time from LOS state to Rx LOS assert | |||||
LOS Deassert Time | t_loss_off |
| 100 | µsec | Time from | ||||||
Serial ID Clock Rate | f_serial_clock |
| 100 | kHz |
|
|
|
|
8 | 2007/11/6 |
| Rev. 0D |
DELTA ELECTRONICS, INC. | www.deltaww.com |