Delta Electronics TSP-10G3A1EER manual Reset Function

Page 9

TSP-10G3A1EER

5 MOD_ABS

Mod_ABS is pulled up to Host_Vcc on the host board and grounded in the XFP module. Mod_ABS is then asserted Highwhen the XFP module is physically absent from a host slot.

6 RX_LOS

The RX_LOS when High indicates insuf.cient optical power for reliable signal reception. The RX_LOS pin is an open collector output and must be pulled up to Host_Vcc on the host board.

7 P_DOWN/RST

This is a multifunction pin for module Power Down and Reset. The P_Down/RST pin must be pulled up to VCC3 in the XFP module.

7.1 POWER DOWN FUNCTION

The P_Down pin, when held High by the host, places the module in the standby (Low Power) mode with a maximum power dissipation of 1.5W.

This protects hosts which are not capable of cooling higher power modules which may be accidentally inserted. The modules 2-wire serial interface and all laser safety functions must be fully functional in this low power mode. During P_Down, the module shall still support the completion of reset Interrupt, as well as maintain functionality of the variable power supply as described in XFP MSA Revision 3.1 section 5.7.

7.2 RESET FUNCTION

The negative edge of P_Down/RST signal initiates a complete module reset.

7.3 MODULE BEHAVIOR DURING POWER DOWN AND RESET

During execution of a reset (t_init) or while held in Power Down mode, a module may be unable to determine the correct value for Mod_NR and RX_LOS. These outputs as well as all interrupt related .ags, except completion of Reset .ag, shall be disregarded by the host. When the module completes a Reset and is not in Power Down mode, the module must represent the correct value of both signals on its outputs before posting a completion of reset interrupt to the host (see XFP MSA Revision 3.1 Table 39, bit 0 register address 84).

At no time shall a module cause spurious assertion of the Interrupt pin.

When a host initially applies power to a module with the P_Down/RST signal asserted, a module comes up in power down mode. The module shall only assert the Interrupt signal pin to informthe host it has completed a reset. The completion of reset .ag (see XFP MSA Revision 3.1 Table 39, bit 0 register address 84) shall be the only interrupt source .ag set during power down mode.

The host is expected to clear this interrupt before releasing the module from the power down mode. The transition from power down mode to normal mode will trigger a reset of the module and result in a 2nd module reset and a 2nd reset completion interrupt to the host

9

Revision: S3

 

04/10/2007

DELTA ELECTRONICS, INC.

www.deltaww.com

Image 9
Contents Application Description10Gbps XFI electrical signal Parameter Symbol Min Typ Max UnitsAbsolute Maximum Ratings Recommended Operating ConditionsOptical Transmitter Characteristics TA=0 ºC to 70 ºC Parameter Symbol Min Typ Max Units NotesOMA RSO Optical Receive Characteristics TA=0 ºC to 70 ºCLOS D LOS aParameter C’ Symbol Min Typ Max Units XFI Module Receiver Output Jitter Specifications at C’Pin Description LVTTL-I GNDLVTTL-O LVTTL-I TxdisModnr Low Speed Electrical Hardware PinsReset Function Memory Map of Management Interface Mechanical Outline Dimensions Latch Color IdentifierBeige Regulatory Compliance Feature Test Method Reference PerformanceAppendix A. Document Revision Version No Date Description