Please thoroughly read this instruction sheet before installing option cards and putting them into use.
The content of this instruction sheet may be revised without prior notice. Please consult our distributors or download the most updated version at http://www.delta.com.tw/industrialautomation.
XLayout
PG Card
[ Specification
Environmental
| Operating Temperature | |
| Storage Temperature | |
| Ambient Humidity | Less than 90%RH |
| Installation Altitude | Below 1000m |
| Vibration | Below 20 Hz: Maximum 9.81 m/s2 (1G); |
| 20 ~ 50Hz: Maximum 5.88 m/s2 (0.6G) | |
|
|
Terminals Descriptions
Pulse Feedback | Pulse Output |
YInstallation
Make sure that the AC Motor Drive is powered off before operation. DO NOT insert or remove the card when the AC Motor Drive is powered on.
Please mount the extension card as shown and fix it with the screw packed with the card.
Screw torque:
Maximum
Terminal Symbols
Vcc
0V
A, A
B, B
A/O, B/O
Descriptions
Input Voltage: DC 5 ~ 24V
When the encoder output type is voltage output, input voltage is DC 12 ~ 24V
Power source and input signal common
Input signal from the encoder. Input type is selected by SW2. It can be
Maximum 300KP/sec
Output signal from the encoder.
Open collector: max. output DC24V 50mA
Grounding
Terminals Screw Torque: Maximum
Wire Length
Types of Encoder Output | Maximum Length | Wire Gauge |
|
Voltage | 50m | 14 ~ 24 AWG |
|
Open Collector | 50m |
| |
Line Driver | 300m | (2.1 ~ 0.2 mm2 ) |
|
Complementary | 70m |
|
|
NOTE
Only when the extension card is correctly installed on the AC Motor Drive, the extension card will be automatically detected. The parameters can be set in Group 13. If extension card is not installed, only parameters Group 0 ~ Group 10 can be set. Refer to Chapter 5: Parameters in the user manual for further details.
ZNotes
Please use a shielded cable to prevent interference. Do not run control wires parallel to any high voltage AC power line (200 V and above).
The wire length and signal frequency are in inverse proportion.
Always use this product in a clean indoor location free from dust, corrosive gas and liquid.
When the relays are used to switch inductive loads (relays, contactors, motors, etc), connect an RC network or Varistor parallel to the load to suppress voltage spikes.
For safety, it is recommended to use fuses for the circuitry that is switched by the relays. The fuse specification must be within the specified contact limits.
The ends of wires must be tinned or crimped.
To avoid interference, route the extension card wires separately and as far away (at least 15cm) as possible from other control wires, motor wires and power wires, etc. Where these wires must cross each other, please make sure they are at a 90o angle.
Always use and operate this product within the limit of its specifications.
\Types of Encoder Output
Types of Encoder |
|
| SW2 |
|
| Wiring Diagram |
| |||
Output |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |
VCC |
|
| OC |
|
|
|
|
|
|
|
Voltage |
|
|
|
| NFB |
|
|
|
| |
| O/P |
| R | R(L1) | U(T1) |
|
|
| ||
|
|
|
|
|
| |||||
|
|
| TP |
|
|
|
| Motor | ||
|
|
| S |
| S(L2) | V(T2) |
|
| ||
| 0V |
|
|
|
|
| 3~ | |||
|
|
| OC | T |
| T(L3) | W(T3) |
|
| |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |
|
| Q |
|
|
|
|
|
|
|
|
Line driver |
|
|
|
|
| A | A |
| ||
|
|
| TP |
|
| A | Vin | |||
|
| Q |
|
|
|
| A | |||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| B | B PG | ||
|
|
|
|
|
|
|
| B | GND | |
|
|
|
|
|
|
|
| B | ||
|
|
|
|
|
|
|
| + | ||
|
|
|
|
|
| OC |
|
| ||
|
|
|
|
|
|
| Vcc |
| ||
|
|
| OC |
|
|
|
| DC | ||
|
|
|
|
|
|
| 0V |
| 5~24V | |
VCC |
|
|
|
|
|
|
|
|
| - |
|
|
|
|
|
|
|
|
|
| |
Complementary |
| O/P |
|
|
| TP |
| A/O | RPM Meter | |
|
|
|
|
|
| B/O | ||||
|
|
|
|
|
|
|
|
|
| |
|
|
| TP |
|
|
|
| 0V | *The power source of RPM meter | |
|
|
|
|
|
|
|
| |||
| 0V |
|
|
|
|
|
| is supplied by the customers. | ||
|
|
|
|
| NFB |
|
|
|
| |
|
|
|
| R | R(L1) | U(T1) |
|
|
| |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| Motor | ||
|
|
|
| S |
| S(L2) | V(T2) |
|
| |
|
|
|
|
|
|
| 3~ | |||
|
|
|
|
|
|
|
| |||
|
|
|
| T |
| T(L3) | W(T3) |
|
| |
|
|
|
|
|
|
|
|
| ||
VCC |
|
| OC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| A | A | Vin | ||
|
| O/P |
|
|
|
|
| A | PG | |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| B |
| |
|
|
| TP |
|
|
|
| B | GND | |
|
|
|
|
|
|
| B | |||
|
|
|
|
|
|
| + | |||
Open | 0V |
|
| OC |
|
| ||||
|
|
|
| Vcc |
| 5~24V | ||||
|
|
|
|
|
| DC | ||||
collector |
|
|
|
|
|
|
| 0V |
| - |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| TP |
| A/O |
|
|
|
|
|
|
|
|
|
| B/O | RPM Meter | |
|
|
|
|
|
|
|
| 0V | ||
|
|
|
|
|
|
|
| *The power source of RPM meter | ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| is supplied by the customers. |
Note: Based on the design, the input signal terminals from the encoder should be connected to the terminals
of A and B on