THERMAL CURVES (NC12S0A0V15)
FACING PWB
AIR VELOCITY
AND AMBIENT
TEMPERATURE
MEASURED BELOW
THE MODULE
PWB
MODULE
50.8 (2.0”)
AIR FLOW
17.5 (0.69”) 35 (1.38”)
NC12S0A0V15 (Standard) Output Current vs. Ambient Temperature and Air Velocity
Output Current(A) | @ Vout = 3.3V (Either Orientation) |
15 |
|
|
|
|
|
|
|
|
|
|
|
|
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Natural |
|
|
|
|
|
|
|
|
|
|
9 | Convection |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
| 100LFM |
|
|
|
|
|
|
|
|
|
| |
| 200LFM |
|
|
|
|
|
|
|
|
|
| |
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 300LFM |
|
|
|
|
|
|
|
|
|
|
|
| 400LFM |
|
|
|
|
|
|
|
|
|
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
|
|
|
|
|
|
25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 | 75 | 80 | 85 |
|
|
|
|
|
|
|
|
|
| Ambient Temperature (℃) |
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
Figure 32: Wind tunnel test setup
Figure 33: Temperature measurement location
* The allowed maximum hot spot temperature is defined at 130℃
NC12S0A0V15 (Standard) Output Current vs. Ambient Temperature and Air Velocity
Output Current(A) | @ Vout = 5V (Either Orientation) |
15 |
|
|
|
|
|
|
|
|
|
|
|
|
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Natural |
|
|
|
|
|
|
|
|
|
|
9 | Convection |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
| 100LFM |
|
|
|
|
|
|
|
|
|
| |
| 200LFM |
|
|
|
|
|
|
|
|
|
| |
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 300LFM |
|
|
|
|
|
|
|
|
|
|
|
| 400LFM |
|
|
|
|
|
|
|
|
|
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
|
|
|
|
|
|
25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 | 75 | 80 | 85 |
|
|
|
|
|
|
|
|
|
| Ambient Temperature (℃) |
Figure 34: Output current vs. ambient temperature and air
velocity@Vout=5V(Either Orientation) NC12S15A_01102008
Figure 35: Output current vs. ambient temperature and air velocity@ Vout=3.3V(Either Orientation)
NC12S0A0V15 (Standard) Output Current vs. Ambient Temperature and Air Velocity
Output Current(A) | @ Vout = 1.8V (Either Orientation) |
15 |
|
|
|
|
|
|
|
|
|
|
|
|
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Natural |
|
|
|
|
|
|
|
|
|
|
9 | Convection |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
| 100LFM |
|
|
|
|
|
|
|
|
|
| |
| 200LFM |
|
|
|
|
|
|
|
|
|
| |
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 300LFM |
|
|
|
|
|
|
|
|
|
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
|
|
|
|
|
|
25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 | 75 | 80 | 85 |
|
|
|
|
|
|
|
|
|
| Ambient Temperature (℃) |
Figure 36: Output current vs. ambient temperature and air velocity@ Vout=1.8V(Either Orientation)
NC12S0A0V15 (Standard) Output Current vs. Ambient Temperature and Air Velocity
Output Current(A) | @ Vout = 0.9V (Either Orientation) |
15 |
|
|
|
|
|
|
|
|
|
|
|
|
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Natural |
|
|
|
|
|
|
|
|
|
|
9 | Convection |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
| 100LFM |
|
|
|
|
|
|
|
|
|
| |
| 200LFM |
|
|
|
|
|
|
|
|
|
| |
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 300LFM |
|
|
|
|
|
|
|
|
|
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
|
|
|
|
|
|
25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 | 75 | 80 | 85 |
|
|
|
|
|
|
|
|
|
| Ambient Temperature (℃) |
Figure 37: Output current vs. ambient temperature and air velocity@ Vout=0.9V(Either Orientation)