Delta Electronics Series 240W manual Scope Resistive Load

Page 6

ELECTRICAL CHARACTERISTICS CURVES

Figure 12: Input Terminal Ripple Current, ic, at full rated output current and nominal input voltage with 12µH source impedance and 47µF electrolytic capacitor (100 mA/div, 2us/div).

Figure 13: Input reflected ripple current, is, through a 12µH source inductor at nominal input voltage and rated load current (20 mA/div, 20us/div).

Vo(+)

Vo(-)

Copper Strip

10u

1u

SCOPE

RESISTIVE

 

LOAD

 

 

 

Figure 14: Output voltage noise and ripple measurement test

Figure 15: Output voltage ripple at nominal input voltage and

setup.

rated load current (50 mV/div, 2us/div). Load capacitance: 1µF

 

ceramic capacitor and 10µF tantalum capacitor. Bandwidth: 20

 

MHz. Scope measurements should be made using a BNC cable

 

(length shorter than 20 inches). Position the load between 51

 

mm to 76 mm (2 inches to 3 inches) from the module.

DS_E48SB12020_05222008

6

Image 6
Contents Features Technical Specifications ParameterElectrical Characteristics Curves 38Vin 48Vin 55VinFor Negative Remote On/Off Logic Electrical Characteristics Curves Scope Resistive Load Features Descriptions Design ConsiderationsOver-Temperature Protection Remote On/OffThermal Testing Setup Thermal ConsiderationsThermal Derating Pin Specification Mechanical DrawingPin No Name Function Part Numbering System Model List