Omron V600-HA Sensor, Transmission Distance Specifications, Recommended Combinations

Page 3

Sensor

Model

V600-HS51

V600-HS61

V600-HS63

V600-HS67

Shape

 

 

 

 

Item

 

 

 

 

Transmission frequency

530 kHz

 

 

 

Ambient temperature

10 to 60°C

 

10 to 70°C

 

Storage temperature

25 to 75°C

 

 

 

Ambient humidity

35% to 95%

 

 

 

Insulation resistance

50 M(at 500 VDC) between cable terminal and case

 

 

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between cable terminal and case (leakage current: 1 mA max.)

 

 

 

 

Degree of protection

IEC60529: IP67

 

 

 

 

 

 

Vibration resistance

Destruction: 10 to 2,000 Hz, 3-mm double amplitude, with

Destruction: 10 to 500 Hz, 2-mm double amplitude, with 3

 

2 sweeps of 15 min each in 3 directions

sweeps of 11 min each in 3 directions

 

 

 

Shock resistance

Destruction: 981 m/s2, 3 times each in 3 directions (18

Destruction: 490 m/s2, 3 times each in 3 directions (18

 

times total)

times total)

 

 

 

 

 

Cable length

2 m (fixed)

 

 

 

 

 

 

Wireless transmission

16-bit CRC (Cyclic Redundancy Check) in both directions

 

 

error direction

 

 

 

Indicator

---

Power: green

 

 

 

 

 

Weight

Approx. 70 g

Approx. 190 g

Approx. 540 g

 

 

 

 

Transmission Distance Specifications

Recommended Combinations

 

Amplifier

 

V600-HAR91/-HAR81/-HAM91/-HAM81/-HAR92

 

 

 

 

 

 

 

Data Carrier

Sensor

V600-HS51

V600-HS61

V600-HS63

V600-HS67

 

 

 

 

 

 

Memory

V600-D23P53

0.5 to 3.0 mm

0.5 to 3.0 mm

---

---

EEPROM

 

 

 

 

 

V600-D23P54

0.5 to 5.0 mm

0.5 to 5.5 mm

---

---

(Battery-

 

 

 

 

 

less type)

V600-D23P55

0.5 to 7.0 mm

0.5 to 7.0 mm

0.5 to 9.5 mm

---

 

 

 

 

 

 

 

V600-D23P61

0.5 to 8.0 mm

0.5 to 9.0 mm

2 to 16 mm

---

 

 

 

 

 

 

 

V600-D23P66N

---

---

5 to 30 mm

5 to 35 mm

 

 

 

 

 

 

 

V600-D23P66SP

---

---

5 to 25 mm

5 to 30 mm

 

 

 

 

 

 

 

V600-D23P71

---

---

5 to 35 mm

10 to 70 mm

 

 

 

 

 

 

 

V600-D23P72

---

0.5 to 18 mm

5 to 35 mm

10 to 50 mm

 

 

 

 

 

 

Memory

V600-D8KR12

5 to 15 mm

5 to 18 mm

5 to 45 mm

10 to 60 mm

SRAM

 

 

 

 

 

V600-D8KR13

---

---

10 to 30 mm

10 to 40 mm

(Built-in-

 

 

 

 

 

battery

V600-D8KR04

---

---

10 to 65 mm

10 to 100 mm

type)

 

 

 

 

 

V600-D2KR16

---

---

2 to 15 mm

---

 

 

 

 

 

 

 

Note: 1. The specifications take fluctuations in ambient temperature and slight differences between products into account.

2.The read distance and write distance are the same.

3.Sensor Installation Conditions

V600-HS51:When flush-mounted in iron Axial offset from the Data Carrier: ±2.0 mm

V600-HS61: When surface-mounted on metal (ferrous) Axial offset from the Data Carrier: ±2.0 mm

V600-HS63: When surface-mounted on metal (ferrous) Axial offset from the Data Carrier: ±10.0 mm

V600-HS67: When surface-mounted on metal (ferrous) Axial offset from the Data Carrier: ±10.0 mm

4.Data Carrier Installation Conditions

V600-D23P53/-P54: When flush-mounted in iron

V600-D23P55/-P66N/-P66SP/-P71/-P72: When surface-mounted on resin (no metal on the backside)

V600-D23P61: When surface-mounted on metal (ferrous)

V600-D8KR12/-13/-04: When surface-mounted on metal (ferrous)

V600-D2KR16: When the Data Carrier attached to the holder is mounted on a metal (ferrous) surface

5.The transmission distance specified in the specifications is also applicable when the Data Carrier is mounted on non-metallic surfaces.

6.The Data Carrier is stationary.

4Intelligent Flag I/II V600-HA

Image 3
Contents Output Ordering Information/SpecificationsAmplifier InputV600-HAM91/-HAM81 Multi-functional type FunctionsInterface Cable V600-HAR91/-HAR81 Read-only typeTransmission Distance Specifications SensorRecommended Combinations HAM81 System ConfigurationCombinations with the V600-HS61 Sensor Characteristic Data TypicalTransmission Range Combinations with the V600-HS51 SensorCombinations with the V600-HS63 Sensor Combinations with the V600-HS67 Sensor Transmission TimeCircuit Configuration PrecautionsInput/Output Correct Use Dimensions AmplifierV600-HAR91/-HAR81 V600-HAM91/-HAM81 V600-HS61 SensorV600-HAR92 V600-HS51V600-A6@R for V600-HAR91/-HAR81 Interface CableV600-HS63 V600-HS67Model V600-A6@M for V600-HAM91/-HAM81/-HAR92Terms and Conditions WARRANTY, Limitations of Liability

V600-HA specifications

The Omron V600-HA is a cutting-edge temperature controller designed to meet the rigorous demands of industrial applications. It integrates advanced technologies and robust features to provide precise and reliable temperature management, making it an invaluable asset across various sectors, including manufacturing, food processing, and HVAC systems.

One of the standout features of the V600-HA is its exceptional control capabilities. It utilizes a proprietary PID (Proportional, Integral, Derivative) algorithm that enables it to maintain stable temperature levels with minimal deviation. This level of precision is critical in applications where temperature fluctuations can lead to product quality issues or operational inefficiencies.

In terms of technology, the V600-HA is equipped with a dual-display LCD that provides users with clear visibility of the current temperature, setpoint, and operational status. The user interface is intuitive, allowing for easy navigation through various settings and parameters. This accessibility ensures that operators can quickly make adjustments as needed without extensive training.

The V600-HA also features advanced communication capabilities, including support for protocols like Modbus and Ethernet. This connectivity allows for seamless integration with existing control systems, enabling remote monitoring and control. By leveraging these communication protocols, businesses can enhance operational efficiency and data collection, critical for process optimization.

Moreover, the controller boasts flexible input options. It supports various types of thermocouples and RTDs (Resistance Temperature Detectors), allowing it to be used in a wide range of temperature measurement scenarios. This versatility makes the V600-HA an excellent choice for diverse applications across different industries.

Another key characteristic of the Omron V600-HA is its robust construction. Designed for durability, it can withstand challenging environments, including extreme temperatures and vibrations often found in industrial settings. This rugged design contributes to a longer lifespan and reduced maintenance costs, ultimately enhancing productivity.

Additionally, the V600-HA incorporates safety features such as output limit control and alarm functions. These features help to preemptively address potential issues, ensuring safe operation and minimizing the risk of equipment damage or product loss.

In conclusion, the Omron V600-HA temperature controller stands out for its precise control capabilities, user-friendly design, advanced communication technologies, and robust construction. These features make it a reliable solution for industries that require stringent temperature management, ultimately driving efficiency and quality in operations.