Chauvet 3 user manual Appendix, General Troubleshooting

Page 9

5.APPENDIX

General Troubleshooting

SYMPTOM

POSSIBLE CAUSE(S)

POSSIBLE ACTION(S)

 

∙ Excessive circuit load

∙ Check total load placed on the

Breaker/Fuse

electrical circuit.

 

keeps blowing

∙ Short circuit along the power

∙ Check for a short in the electrical

 

wires

wiring (internal and/or external).

Device does not

∙ No power

∙ Check for power on Mains.

power up

∙ Loose power cord

∙ Check power cord

 

∙ Wrong DMX addressing

∙ Check Control Panel and unit

 

addressing

 

 

 

∙ Damaged DMX cables

∙ Check DMX cables

Fixture is not

∙ Wrong polarity settings on the

∙ Check polarity switch settings on

responding to DMX

controller

the controller

 

∙ Loose DMX cables

∙ Check cable connections

 

∙ Faulty DMX interface

∙ Replace DMX input

 

∙ Faulty Main PCB

∙ Replace Main PCB

 

∙ Non DMX cables

∙ Use only DMX compatible cables

 

∙ Bouncing signals

∙ Install terminator as suggested.

 

∙ Long cable / Low level signal

∙ Install amplifier right after fixture

Loss of signal

with strong signal.

 

 

∙ Install an optically coupled DMX

 

∙ Too many fixtures

 

splitter after unit #32.

 

 

 

∙ Interference from AC wires

∙ Keep DMX cables separated from

 

power cables or black lights.

 

 

If you still have a problem after trying the above solutions, please contact CHAUVET®

Technical Support.

5. Appendix

9

Image 9
Contents Page Table of Contents Before YOU Begin Safety Instructions Product Overview IntroductionSetup AC PowerPower Linking Orientation MountingMaster/Slave Mode Standalone Configuring the Starting AddressOperating Instructions DMX Channel ValuesAppendix General TroubleshootingFixture Linking Daisy Chain DMX PrimerData Cabling DMX Data CableSetting the Starting Address Cable ConnectorsSetting up a DMX Daisy Chain Pin to 5-Pin Conversion ChartReturns Procedure General MaintenancePower Technical SpecificationsWorld Wide Contact US