RS-232C Communication / Network command table (continued)

Names

Operation Type

 

Header

 

 

 

Command Data

 

 

CRC

Action

Type

Setting code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO

BE EF

 

03

 

06 00

86 D8

01 00

22 20

00 00

HDMI RANGE

Set

NORMAL

BE EF

 

03

 

06 00

16 D9

01 00

22 20

01 00

 

ENHANCED

BE EF

 

03

 

06 00

E6 D9

01 00

22 20

02 00

 

 

 

 

 

 

Get

BE EF

 

03

 

06 00

B5 D8

02 00

22 20

00 00

COMPUTER IN1

Set

AUTO

BE EF

 

03

 

06 00

CE D6

01 00

10 20

03 00

SYNC ON G OFF

BE EF

 

03

 

06 00

5E

D7

01 00

10 20

02 00

 

 

Get

BE EF

 

03

 

06 00

0D D6

02 00

10 20

00 00

COMPUTER IN2

Set

AUTO

BE EF

 

03

 

06 00

32

D7

01 00

11 20

03 00

SYNC ON G OFF

BE EF

 

03

 

06 00

A2

D6

01 00

11 20

02 00

 

 

Get

BE EF

 

03

 

06 00

F1

D7

02 00

11 20

00 00

FRAME LOCK –

Set

OFF

BE EF

 

03

 

06 00

3B

C2

01 00

50 30

00 00

ON

BE EF

 

03

 

06 00

AB C3

01 00

50 30

01 00

COMPUTER IN1

 

 

 

 

Get

BE EF

 

03

 

06 00

08

C2

02 00

50 30

00 00

 

 

 

 

FRAME LOCK –

Set

OFF

BE EF

 

03

 

06 00

0B

C3

01 00

54 30

00 00

ON

BE EF

 

03

 

06 00

9B

C2

01 00

54 30

01 00

COMPUTER IN2

 

 

 

 

Get

BE EF

 

03

 

06 00

38

C3

02 00

54 30

00 00

 

 

 

 

FRAME LOCK -

Set

OFF

BE EF

 

03

 

06 00

7F C2

01 00

53 30

00 00

ON

BE EF

 

03

 

06 00

EF C3

01 00

53 30

01 00

HDMI

 

 

 

 

Get

BE EF

 

03

 

06 00

4C C2

02 00

53 30

00 00

 

 

 

 

D-ZOOM

 

Get

BE EF

 

03

 

06 00

D0 D0

02 00

0A 30

00 00

 

Increment

BE EF

 

03

 

06 00

B6

D0

04 00

0A 30

00 00

 

 

Decrement

BE EF

 

03

 

06 00

67

D1

05 00

0A 30

00 00

D-ZOOM Reset

 

Execute

BE EF

 

03

 

06 00

98

C9

06 00

70 70

00 00

D-SHIFT V

 

Get

BE EF

 

03

 

06 00

2C D1

02 00

0B 30

00 00

 

Increment

BE EF

 

03

 

06 00

4A D1

04 00

0B 30

00 00

 

 

Decrement

BE EF

 

03

 

06 00

9B

D0

05 00

0B 30

00 00

D-SHIFT V

 

Execute

BE EF

 

03

 

06 00

A8

C8

06 00

74 70

00 00

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D-SHIFT H

 

Get

BE EF

 

03

 

06 00

58

D0

02 00

0C 30

00 00

 

Increment

BE EF

 

03

 

06 00

3E

D0

04 00

0C 30

00 00

 

 

Decrement

BE EF

 

03

 

06 00

EF D1

05 00

0C 30

00 00

D-SHIFT H

 

Execute

BE EF

 

03

 

06 00

54

C9

06 00

75 70

00 00

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOP

BE EF

 

03

 

06 00

02

D0

01 00

09 20

02 00

PICTURE

Set

MIDDLE

BE EF

 

03

 

06 00

62

D1

01 00

09 20

00 00

POSITION

 

BOTTOM

BE EF

 

03

 

06 00

F2

D0

01 00

09 20

01 00

 

 

Get

BE EF

 

03

 

06 00

51

D1

02 00

09 20

00 00

KEYSTONE V

 

Get

BE EF

 

03

 

06 00

B9

D3

02 00

07 20

00 00

 

Increment

BE EF

 

03

 

06 00

DF D3

04 00

07 20

00 00

 

 

Decrement

BE EF

 

03

 

06 00

0E

D2

05 00

07 20

00 00

KEYSTONE V

 

Execute

BE EF

 

03

 

06 00

08

D0

06 00

0C 70

00 00

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KEYSTONE H

 

Get

BE EF

 

03

 

06 00

E9

D0

02 00

0B 20

00 00

 

Increment

BE EF

 

03

 

06 00

8F

D0

04 00

0B 20

00 00

 

 

Decrement

BE EF

 

03

 

06 00

5E

D1

05 00

0B 20

00 00

KEYSTONE H

 

Execute

BE EF

 

03

 

06 00

98

D8

06 00

20 70

00 00

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PERFECT FIT

Set

Disable

BE EF

 

03

 

06 00

FE 88

01 00

20 21

00 00

Enable

BE EF

 

03

 

06 00

6E 89

01 00

20 21

01 00

 

 

Get

BE EF

 

03

 

06 00

CD 88

02 00

20 21

00 00

(continued on next page)

22

Image 22
Contents Example of computer signal CP-A220N/CP-A300NInitial set signals Connection to the ports Computer IN1, B Computer IN2, C Monitor OUTVideo SDA SCLCEC USB Type a To input component video signal to Computer in ports Connection RS-232C CommunicationCommunicaion settings CRCResponse code / Error code h shows hexadecimal Command Control via the Network Communicaion Port Port1 PortCommand control settings TCP #9715 Command formatAuthentication Automatic Connection BreakNetwork Bridge Communication Communication settings Operating GuideRS-232C Communication / Network command table Gamma Gain G Color TempGain R Gain BColor Offset BColor Temp Offset B TintSize PhaseAuto Adjust ExecuteComputer IN2 Hdmi RangeComputer IN1 Frame LockPerfect Auto ECOMirror ECO ModeVolume Monitor OUTVolume USB Volume HdmiVolume LAN Type aMIC Level MIC VolumeHdmi Audio LanguageMenu Position H MenuPosition H Menu PositionTemplate Power onAuto Power DisplayMY BUTTON-1 MY BUTTON-2Normal MY SourceRemote Freq HighPJLink command Avmt ?Lamp ?