Acer M190E5-L0A manual Test point

Page 11

(2)Definition of Contrast Ratio (CR):

The contrast ratio can be calculated by the following expression and figure below. Contrast Ratio (CR) = L255 / L0

L255: Luminance of gray level 255

L 0: Luminance of gray level 0

CR = CR (5)

CR (X) is corresponding to the Contrast Ratio of the point X at Figure in Note (5).

Definition of luminance measured points and Brightness Uniformity:

Horizontal Line Number [pixel]

Number [pixel]

X

: Test point

Vertical Line

 

 

Active area

Delta X=17.0mm;Delta Y=17.0mm

Luminance of center point: L=L (1)

Brightness Uniformity Measurement points: Five specified points 1-5

Formula: Maximum [L (1), L (2), L (3), L (4), L (5), L (6), L (7), L (8), L (9), L (10), L (11), L (12), L (13)]/Minimum [L (1), L (2), L (3), L (4), L (5), L (6), L (7), L (8), L (9), L (10), L (11), L (12), L (13)]

11

Image 11
Contents Acer AL1917 Service Guide Page Page Page Page Page Table of Contents Test Conditions FeaturesSpecification Unit LCD panel Specification Technical SpecificationDefinition of Viewing Angle θx, θ y Test point Definition of Response Time TR, TF and Measurement Method Function Name Front 齇鷘 蘠 矏藜Back OSD Menu Description OSD Menu Screen OSD ControlPage Description OSD Function DefinitionPlug and Play Power SaverDisassembly Procedures Page Page Page Assembly Procedures Page Page Page Abnormal Display Troubleshooting Page Abnormal ON/OFF, LCD display, Keyboard Troubleshooting Abnormal BIOS, OSD, Other Display Troubleshooting Audio Abnormal Troubleshooting Function Block Diagram AC Connector Ac power jack Sub mini 15pin ConnectorAudio Connector Chapter Picture Part name Description Vendor Part No Page Explosion Diagram