Electrical Requirements
Standard Test Conditions
All tests shall be performed under the following conditions, unless otherwise specified.
Ambient light | Dark room (< 1 cd/m2) |
|
|
Viewing distance | 40 cm for LCD performance, 20 cm for LCD failures |
Warm up time | >30 minutes |
|
|
Analog Input signal | 700 mVss |
Control temperature | 6500°K |
|
|
Brightness control | The value under user mode |
| Set to The value under user mode, which allows that the brightest |
User contrast control | two of 32 linear distributed |
| distinguished. |
Picture position and size | Factory preset value |
|
|
Viewing angle | 90 ° H and V |
AC Supply voltage | 230V± 5%, 50±3Hz |
Ambient temperature | 20+5℃ |
Humidity | 65% ± 20% |
Display mode | 1680x1050, 60 Hz, all white |
|
|
Set to “User” mode |
Measurement systems
The units of measure stated in this document are listed below: 1 gamma = 1 nano tesla
1 tesla = 10,000 gauss cm = in x 2.54
Lb = kg x 2.2
Degrees F = [°C x 1.8] + 32 Degrees C = [°F - 32]/1.8 u' =
v' =
x = (27u'/4)/[(9u'/2) - 12v' + 9] y = (3v')/[(9u'/2) - 12v' + 9] nits = cd/(m2) =