Checking the accuracy of the vertical en plumbing:
(only Lino P3, Lino P5 and Lino L2P5)
Place the Lock switch 3 in the "Unlocked" ( ) position.
Checking the upper plumbing point:
B1 | B2 max. 2 mm |
| 1.5 m |
1 | 2 |
| A1 |
Checking the lower plumbing point:
| A1 |
1 | 2 |
| 1.5 m |
B1 | B2 max. 2 mm |
Set up the laser on its tripod or wall mount bracket near point A1 at a minimum distance of 1.5 m from point B1. The horizontal laser is aligned in direction 1. Mark the laser dots A1 and B1 with a pin.
Rotate the instrument by 180° so that it points in the opposite direction 2 to direction 1. Adjust the instru- ment so that the laser beam hits point A1 exactly. If point B2 is no further than 2 mm away from point B1, then the Leica Lino is within tolerance.
)Should your Leica Lino be outside of the spec- ified tolerance, please contact an authorised dealer- ship or Leica Geosystems.
Display notices
Falling below or exceeding the permissible temperature range:
The laser switches off and all symbols flash.
Outside of the
The laser switches off and the symbol of the function used starts to flash.
Pendulum locked:
(only Lino L360, L2P5, L2+, and L2)
The laser beam is not levelled and the Lock symbol 7 lights up.
Operation
10
Leica Lino 757665g en