Mitsubishi Electronics UD8850U, UD8900U manual SIGNAL menu, 5.6.7, NETWORK menu

Page 16

5.6.6 SIGNAL menu

ITEM

 

 

Function

Data

Character

 

ASCII code

 

 

 

MEMORY CALL

MMC

4Dh 4Dh 43h

0 (AUTO), 1 to 8 (MEMORY 1 to 8)

HORIZ.POSITION

HP

48h

50h

 

+ (increment), - (decrement)*1

VERT. POSITION

VP

56h

50h

 

+ (increment), - (decrement)*1

FINE SYNC.

FN

46h

4Eh

 

00–31

TRACKING

TRK

54h

52h

4Bh

+ (increment), - (decrement)*1

COMPUTER INPUT

CIN

43h

49h

4Eh

0 (RGB), 1 (YCBCR/YPBPR), 2 (AUTO)

OVER SCAN

VOS

56h

4Fh 53h

00 (90%) – 10 (100%)

HOLD

HLD

48h

4Ch 44h

0 (OFF), 1 (ON)

HOLD BEGIN

HLB

48h

4Ch 42h

00–99

HOLD END

HLE

48h

4Ch 45h

00–99

ASPECT

SC

53h

43h

 

0 (NORMAL, 1 (16:9), 2 (NATIVE), 3 (FULL),

 

 

 

 

 

4 (USER)

ASPECT-USER-

ZMH

5Ah 4Dh 48h

050 to 500

ZOOM(H)

 

 

 

 

NAK is returned when the ASPECT setting is other

 

 

 

 

 

than USER.

ASPECT-USER-ZOOM(V)

ZMV

5Ah 4Dh 56h

050 to 500

 

 

 

 

 

NAK is returned when the ASPECT setting is other

 

 

 

 

 

than USER.

ASPECT-USER-HORIZ.

AHP*

41h

48h

50h

*:+, -

POSITION

 

 

 

 

+:incriment -:decriment

 

 

 

 

 

NAK is returned when the ASPECT setting is other

 

 

 

 

 

than USER.

ASPECT-USER-VERT.

AVP*

41h

56h

50h

*:+, -

POSITION

 

 

 

 

+:incriment -:decriment

 

 

 

 

 

NAK is returned when the ASPECT setting is other

 

 

 

 

 

than USER.

ASPECT-USER-RASTER

RPH*

52h

50h

48h

*:+, -

POSITION(H)

 

 

 

 

+:incriment -:decriment

 

 

 

 

 

NAK is returned when the ASPECT setting is other

 

 

 

 

 

than USER.

ASPECT-USER-RASTER

RPV*

52h

50h

56h

*:+, -

POSITION(V)

 

 

 

 

+:incriment -:decriment

 

 

 

 

 

NAK is returned when the ASPECT setting is other

 

 

 

 

 

than USER.

ASPECT-USER-RESET

ASRST

41h

53h

52h 53h 54h

The setting contents of ASPECT USER are reset.

 

 

 

 

 

NAK is returned when the ASPECT setting is other

 

 

 

 

 

than USER.

CLAMP POSITION

CLP

43h

4Ch 50h

001 to 255

CLAMP WIDTH

CLW

43h

4Ch 57h

01 to 63

VERT. SYNC.

VSC

56h

53h

43h

0 (AUTO), 1 (OFF)

LPF

LPF

4Ch 50h 46h

0 (OFF), 1 (ON)

SHUTTER(U)

SHU

53h

48h

55h

000 to 259

SHUTTER(L)

SHL

53h

48h

4Ch

000 to 259

SHUTTER(LS)

SHLS

53h

48h

4Ch 53h

000 to 311

SHUTTER(RS)

SHRS

53h

48h

52h 53h

000 to 311

*1) Setting range differs depending on the input signals.

5.6.7

NETWORK menu

 

 

 

 

 

 

 

 

 

 

 

 

ITEM

 

Function

Data

 

 

Character

ASCII code

 

 

 

 

 

PROJECTOR NAME

NAME

4Eh 41h

4Dh 45h

Up to 15 single-byte alphanumeric characters

 

 

 

 

 

 

Effective only during P-ON.

 

NETWORK RESTART

NRCN

4Eh 52h

43h 4Eh

LAN microcomputer is reset and restarted.

 

Some commands are not executed depending on the input signal. The operational restrictions same as those

 

 

on the menu setting are applied. Refer to “Menu operation” in the User Manual for more details.

16

Image 16
Contents Contents Control command conguration4. Execution procedure of RS-232C commands via LAN Command list1. Introduction PC-controllable functionsCompatibility with the former models 1.1 Connection1.2 Interface 1.2.2 Communications format2. Control command configuration 3. Control sequenceWhile using the LAN terminals, the LAN functions take precedence RS-232C control flowchart Method of checking state of projector4. Execution procedure of RS-232C commands via LAN 4f3c5da17b4fb5ed2c994ebbf657675400PRV=ERRA Projector5.1 General control commands 5. Command list5.2 Reading commands 5.2.1 Status read commands 5.2.2 Read commands for items in INFORMATION menu 5.2.3 Read commands for other informationExample When checking the currently selected input terminal when the INPUT VIDEO is being selected. Values enclosed in quotation marks are ASCII codes How to set the value 5.6.1 IMAGE menu 5.6.3 INSTALLATION 2 menu 5.6.2 INSTALLATION 1 menu1 SDI function works only on UD8900U 5.6.4 MULTI-SCREEN menu 5.6.5 FEATURE menu is a 4 to 8-digit password comprised of any figures5.6.7 5.6.6 SIGNAL menuNETWORK menu How to set the value When ID is not specified 5.7 Password lock commands