Lamp replacement (continued)
4.Pull up the handle (g), and then pull out the lamp unit (h) by the handle.
(g)
(h)
5. Remove the lamp attachment unit.
•Pull the lamp unit out of the projector slowly. If it is pulled out quickly, the lamp may break, scattering glass fragments.
•Do not spill liquid on the removed lamp unit or do not place it near any flammable object or where children can reach to pre- vent injuries or fire.
When the projector is mounted to the ceiling:
Confirm that the lamp unit (h) is securely held inside the lamp dis- posable bag of the lamp attachment unit. And then loosen the screw
(f)that come with the lamp attachment unit. Then remove the lamp attachment unit.
6.Load a new lamp unit securely into the projector in the right orien- tation.
7.Tighten up the screw (c) using a Phillips screwdriver (+) to secure the lamp cover (d).
•Make sure that the lamp cover is secured firmly. Otherwise, the POWER indicator flashes red and green, disallowing the projec- tor to be powered on.
Reset of the lamp operation time
Plug in the power cord, and reset the lamp operation time by keep pressing the W, X, and POWER buttons on the control panel at the same time.
Important:
•Unless these three buttons are pressed at the same time, the lamp operation time isn’t reset.
•Make sure that the STATUS indicator is lit twice and the lamp oper- ation time is reset successfully.
•The projector doesn’t turn on if the lamp cover isn’t attached securely.
•Be sure to reset the lamp operation time whenever you replace the lamp.
•Do not reset the lamp operation time unless you replace the lamp.
Caution:
•The lamp is fragile. If it is broken, be careful not to cut yourself with glass fragments.
•Contact your dealer for a new lamp.
Interval of lamp replacement
When the lamp shutdown notice is issued, the lamp replacement is recommended even if the lamp is lit normally. Decrease in lumines- cence and/or color brightness indicates that the lamp needs to be replaced. When the lamp operation time exceeds the time elapsed until the lamp shutdown notice*1 is issued, the indicator will blink alter- nately green and red while the lamp is lit (while the lamp is not lit, the indicator will blink red only) and the lamp replacement message will appear on the screen for one minute every time the lamp is turned on. When the lamp operation time exceeds the time elapsed until the lamp shutdown warning*2 is issued, the replacement message (LAMP EXCHANGE) will appear on the screen for one minute at fixed inter- vals*4 thereafter.
When the lamp operation time exceeds the time elapsed until the lamp shutdown*3, the projector automatically shuts off and can’t be used until the lamp is replaced and the lamp operation time is reset.
XD500U
*1 2250 | Hours |
*2 2850 | Hours |
*3 3000 | Hours*5 |
The times above are when LAMP MODE of the INSTALLATION menu is set to LOW. When it is set to STANDARD, this duration will be short- ened.
*4 | These intervals vary depending on the lamp mode setting. |
*5 | When LAMP MODE is set to STANDARD, the time elapsed until |
| the lamp shutdown will be shortened to 2000 hours. |
Important:
•Do not open the lamp cover when the projector is set at a ceiling or a high place. Lamp fragments may fall from the inside if the lamp were broken.
Please contact your dealer when you need to replace the lamp with a new one.
Caution:
•This projector uses a lamp that contains mer- cury. Disposal of the lamp or the projector with the lamp may be regulated due to environ- mental considerations. For disposal or recy- cling information, please contact your local authorities or the Electronic Industries Alli- ance: www.eiae.org. (For US only).