Lamp replacement
The lamp is designed to project the image on the LCD panels. When the lamp no longer functions, replace it with a new one.
Caution:
•Do not remove the lamp immediately after using the projector, you may get burned because of the high temperature of the lamp.
•When you replace the lamp, press the power button to power off, then wait for 120 seconds in
•Do not remove the lamp except for replacement. Careless treatment can cause injury or fire.
•Do not touch the lamp element directly. It may break and cause you to injure or burn yourself.
•Be sure not to drop the lamp lid screw into the pro- jector. Also be sure not to insert metal or any flam- mable objects, it may cause fire or electric shock. If any objects are inserted, please unplug and contact your dealer.
•Install the lamp securely, failure may cause a fire.
•If the light bulb part breaks, some small glass frag- ments may fall out through the small cooling grill, and sticks to the inside of projector or the lamp box. When taking the lamp out, make sure to turn over the projector and hold the handle of the lamp box to avoid injury from the glass fragments.
•Never shake the lamp or hold it in front of your face after removing the lamp box. The glass fragments may fall out and cause injuries to your
eyes and so on.
1. Reverse the projector gently.
(a)
2.Loosen the screws of the lamp lid
(a) using a phillips screwdriver (+).
3.Remove the lamp cover in the direction of the arrow as indi-
cated.
4. Loosen screws (b) using a phillips screwdriver (+), and remove them.
(b)
7.Insert the new lamp securely into the projector body in the right direction.
8.Put the handle back to the holding point.
• Make sure that the handle is locked.
9.Tighten up the screws (b) using a phillips screw- driver (+).
10.Tighten up the screws of the lamp lid using a phillips screwdriver (+).
How to reset the operation time meter
Plug in the power cord, switch on the projector, and reset lamp time by pressing the $, % and POWER buttons on the contro panel simultaneously.
Important:
•If the 3 buttons was not pressed at the same time, the lamp time may not be reset.
•Please confirm the TEMP indicator illuminates about 2 seconds and the lamp time has been reset.
•The projector will not turn on if you do not secure the lamp lid.
•You must reset the operation time meter after you replace the lamp.
•Do not reset the operation time meter unless the lamp has been replaced.
Caution:
•Do not spill liquid on the lamp or place it near flam- mable objects or where children can touch it. Oth- erwise, it could cause injury or fire.
•Be sure that the projector guide is firmly inserted between the right and left lamp guides.
Interval of the lamp replacement
The interval of the lamp replacement about 2,000 hours of consecutive use. Replacement span may differ ac- cording to operating environment, and may be shorter than 2,000 hours. Decreases in luminescence and/or color brightness will indicate that the light source lamp needs to be replaced. When lamp operation time ex- ceeds 1,500 hours, the indicator will flash alternately between green and red (while the lamp is in operation; when the lamp is not in operation, the indicator will appear red only). When the lamp has been used for about 1,900 hours, the message “LAMP!!.” will appear on the screen for one minute everytime the power is turned on. When the lamp has been used for about 2,000 hours, the projector will automatically shut off for safety and the power indicator light will be red. The projector cannot be used until the lamp has been replaced and operation timer has been reset.
ENGLISH
5. Pull up the handle.
6. Hold onto the projector by the handle as you pull out the lamp.
•Pull the lamp out of the projector slowly. Should the light bulb be bro- ken, glass fragments will spill out if
the lamp is pulled out too quickly.
• Once the lamp has been removed, do not spill liquid on it, place it near flammable objects or where chil-
dren can touch it. Otherwise, it will cause injury or fire.
Caution:
•The lamp is fragile. If broken, be careful not to cut yourself with glass fragments.
•The replacement span of the lamp depends on the environment. For replacement lamps, please con- tact your dealer.
The projector automatically shuts off when the lamp is used up in about 2,000 hours and cannot be used until the lamp is replaced and the internal timer is reset.
EN – 23