Before getting started

System requirements

Your computer must conform to the following minimum standards in order to use it with the MAUSB-100.

Compatible operating systems

IBM PC/AT compatible:

Pre-installed Windows 98/98 SE/Me/2000 Professional (referred to as Windows 2000 in this manual)/XP

Power Mac G3/G4, PowerBook G3/G4, iMac/iBook/eMac series: Pre-installed Mac OS 9.0 - 9.2.2/X (v10.1.2 or later)

USB interface compliant with USB Ver. 2.0 or Ver. 1.1

Equipped with CD-ROM drive (required for device driver/utility software installation)

Supported cards

xD-Picture Card 16MB/32MB/64MB/128MB/256MB/512MB (3.3 V)

Precautions

Before using the MAUSB-100, make sure there is adequate space around the computer so that the MAUSB- 100 can be connected properly. If there is not enough space for MAUSB-100 around the computer to allow a direct connection, use the provided USB extension cable.

The MAUSB-100 may not be compatible with your computer hardware, software, or device drivers.

If you connect the MAUSB-100 to a PC via a USB hub, keyboard, or display, the MAUSB-100 may not function properly.

In this case, connect the MAUSB-100 directly to the computer’s USB port or use the provided USB extension cable.

Versions of Windows 98/Me upgraded from Windows 3.1/95, or Windows 2000 upgraded from Windows 95/NT 4.0/NT 3.51 may not work properly. In this case, you may need to reinstall your OS.

Do not release the hold switch, remove the card, disconnect the MAUSB-100 or set the write-protect switch while the red status lamp is lit. Doing so may destroy data on the card or damage the card.

If you do not use the provided utility software when formatting a card in the MAUSB-100, the card may not be recognized by the digital camera. Re-format the card with the digital camera or with the connected computer using the provided utility software.

(Refer to your digital camera’s instruction manual for details on formatting.)

* The provided utility software is not compatible with Mac OS. If you are using a Macintosh, format the card with your digital camera.

The MAUSB-100 does not support a computer power-saving functions. Turn off the power-saving function before you use the MAUSB-100 with your computer.

It is not possible to connect two or more MAUSB-100s to a single PC at the same time.

Do not swing the strap while attaching it to the MAUSB-100. Avoid banging the MAUSB-100 against hard objects.

To remove the cap, pull out the MAUSB-100 while holding down both sides of the cap.

5

Image 5
Contents Reference Manual Introduction Contents Names of parts What’s includedBefore getting started PrecautionsSystem requirements Supported cardsPlace provided Getting startedTurn on the computer 98/98 SE Install98/98 SEInstall Double-click MAUSB100 Double-click Setup.exe When the Add New Hardware Wizard window appears98/98 SE Operation Setting the write-protect switch 98/98 SEOperationInserting a card 98/98 SEOperation Connecting to the computer98/98 SEOperation Removing a card Disconnecting the MAUSB-100 98/98 SEOperationDrag & Drop Copying files from/to a cardBefore formatting the card Formatting a cardHow to uninstall the device driver/utility software 98/98 SE Device driver/utility software is no longer installed Windows Me/2000/XP Install the utility softwareMe/2000/XPInstall Double-click MAUSB100 Double-click Setup Me/2000/XP Operation Setting the write-protect switch Me/2000/XPOperationConnecting to the computer Me/2000/XP  Operation Me/2000/XPOperation Me/2000/XPOperation Disconnecting the MAUSB-100 Me/2000/XPOperation Copying files from/to a card Me/2000/XPOperation Before formatting the card How to uninstall the utility softwareMe/2000/XP How to uninstall the utility software Cont. Me/2000/XP To identify your Mac OS version Mac OS 9 InstallMac OS 9 Operation Setting the write-protect switch Mac OS 9OperationMac OS 9Operation When the card is recognized correctlyDrag & Drop Disconnecting the MAUSB-100 Mac OS 9OperationFormatting a card with the MAUSB-100 Copying files from/to a card Mac OS 9OperationMac OS X Install Mac OS X Operation Setting the write-protect switch Mac OS XOperationMac OS XOperation Disconnecting the MAUSB-100 Mac OS XOperation Formatting the card for Mac OS Copying files from/to a cardCompatible with Windows 98/98 SE/Me/2000/XP Using the provided utility software xDFormatWhen formatting is complete, Format completed. appears Windows TroubleshootingMacintosh Specifications Glossary of Terms Universal Serial USB Bus PowerBus USB Mass StorageVT560901

MAUSB-100 specifications

The Olympus MAUSB-100 is a versatile and innovative digital microscope adapter designed to enhance the capabilities of optical systems in various applications, including education, research, and industrial inspection. This device seamlessly incorporates digital imaging capabilities into traditional optical microscopes, facilitating high-resolution imaging and easy sharing of observations.

One of the standout features of the MAUSB-100 is its user-friendly interface. The device is engineered for simplicity, allowing users to quickly connect the camera to almost any microscope model. This plug-and-play functionality eliminates the need for complex installations and minimizes setup time, making it accessible to both seasoned professionals and novices alike.

In terms of imaging technology, the MAUSB-100 boasts a high-resolution CMOS sensor that captures vibrant, clear images with remarkable detail. The sophisticated image processing algorithms integrated into the device ensure that color accuracy and contrast are optimized, allowing users to visualize specimens in their true form. This feature is particularly beneficial in applications where precise observation is crucial, such as in medical diagnostics and quality control in manufacturing.

Another notable characteristic of the MAUSB-100 is its compatibility with various software platforms. The device can interface with popular imaging software, allowing users to annotate images, measure features, and perform detailed analysis. This flexibility provides researchers and educators with a powerful tool to document findings and share results with colleagues or students in real time.

The MAUSB-100 is compact and lightweight, designed for portability without sacrificing performance. Its robust construction ensures reliability, even in demanding environments. Additionally, the device supports multiple resolutions and frame rates, giving users the freedom to customize their imaging experience based on specific requirements.

Moreover, connectivity options include USB, making it easy to transfer images to computers or other digital devices. This enhances collaboration and data storage, enabling users to compile comprehensive digital records of their work.

Overall, the Olympus MAUSB-100 is a dynamic tool that transforms traditional microscopy. With its high-quality imaging, ease of use, and adaptable features, it serves as an essential instrument for those seeking to elevate their microscopy experience, allowing for greater exploration and understanding in a wide array of scientific fields.