[8] Service Checks
1. Carrier Transport Service Check
| FRU | Action |
|
|
|
1 | System Board | Check the motor for binds,or loose motor pulley. |
|
| Turn the printer off and disconnect CN2 from the system board.Check |
|
| for motor pins shorted to the motor housing.If you find a pin shorted to |
|
| the housing,replace the motor. If the failure remains,replace the system |
|
| board. |
|
|
|
2 | Carrier Transport | A noisy or chattering motor or a motor that fails to turn can be caused |
| Motor | by: |
|
| • An open or short in the motor. |
|
| • An open or short in the motor driver on the system board. |
|
| • A bind in the carrier transport mechanism. |
|
| With the carrier transport motor cable disconnected from the system |
|
| board,check for zero to ten |
|
| the motor: |
|
| |
|
| |
|
| If the readings are incorrect,replace the motor. |
|
|
|
3 | Carrier Guide Rod | Clean the carrier rod. |
|
| Note:Lubricate the carrier guide rod and the carrier rod bearing surface |
|
| with grease. |
|
|
|
4 | Carrier Transport Belt | Check for worn,loose or broken parts. Check for obstructions blocking |
| Idler Pulley Parts | carrier movement. |
| Carrier Frame | Carrier to carrier frame engagement should be lubricated with grease. |
|
|
|
5 | Home Position Sensor | Be sure the carrier returns to the home position after turning the printer |
|
| on. If the carrier moves half way,or if there is an abnormal sound,turn |
|
| the printer off and disconnect CN3 from the system board. Turn the |
|
| printer on and check for 5V dc between |
|
| system board. If the voltage is present,replace the home position |
|
| sensor. If the voltage is not present,replace the system board. |
|
|
|
6 | Maintenance Station | A problem with the maintenance station can cause carrier movement |
|
| problems at the right margin. Go to the ‘Maintenance Station Service |
|
| Check’ on page 3. |
|
|
|