Sharp ER-A440 manual ER-11DK7G, ER-51DK7G

Page 8

ER-12KT7, ER-22KT7

1) Attach two spacers to the keyboard frame.

Yellow

White

Yellow

White

White

Yellow

Attach the yellow spacer to the left lower side, and the white spacer to the right lower side.

2)The key top of the ER-12KT7 and the ER-22KT7 includes the guide pin. Install the key top so that the guide pin is engaged with the spacer attached to the keyboard frame.

(When using 2 × 2 key top installing jig (UKOG-6725BHZZ) for installation)

1)Remove the key label and the key cap from the key top.

2)Attach the key top so that the guide arm is under the jig. Jig

Key top

Guide arm

3)With the jig inserted in the key top, slowly press down the key top until the guide arm is brought into contact with the guide holder A.

Jig

Key top

Guide arm

Guide arm

A

4)Remove the jig under the above condition 3), and press the key top.

5)Check that the key top operates properly.

6)Install the key label and the key cap.

ER-11DK7G, ER-51DK7G

– 7 –

Image 8
Contents SRV Key LKGIM7113RCZZ For U & a versionGeneral SRV. reset Program Loop ResetMaster reset All memory clear Service options Service toolsList of Options OptionsRemoving the TOP Cabinet Printer UnitInstallation procedure Removing the Main PWBRemote Drawer ER-04DW OutlineJournal Near END Parts listExpansion RAM Chip ER-03RA KEY TOP KIT ER-22KT7 ER-12KT7 ER-11KT7ER-11DK7G, ER-51DK7G Copyright 1998 by Sharp Corporation