Aiphone MKW-M manual Wiring Diagram, Mkw-M, Compatible Models MK-1GD

Page 1

Video Modulator with Audio Door Station and CCTV Interface

- INSTRUCTIONS -

The MKW-M adaptor converts a standard CCTV camera's signal to a 2-wire signal, compatible with the MK-1GD, MK-2MCD, and MY series Black & White Video systems. This allows the utilization of a black & white CCTV camera and a separate audio door station (JA-D)* to be used in place of an MK video door station. A motion detector or other activation device can be connected to the Sensor input to trigger the system. The CCTV camera can also be connected to a standard CCTV system for continual viewing and/or recording. The unit is equipped with a relay output to trigger an external device, such as a DVR or video switcher whenever the audio and video to the Aiphone monitor is on.

 

 

SENSOR RELAY MASTER

AUDIO

OUT

IN

NC NC NO NO A1 A2

1 2

 

 

75 OHM

 

VIDEO

 

OFF ON

AIPHONE

 

 

 

 

 

WIRING DIAGRAM:

MKW-M Modulator for Standard CCTV camera and Audio Only door station

 

 

MKW-M

MK or MY Monitor

 

 

MASTER

or Adaptor*

JA-D*

 

A1

 

 

A1

 

(Optional, only if Sensor

 

 

A2

 

A2

input is not used)

AUDIO

 

 

1

 

 

B1

 

 

1

 

 

 

2

 

 

2

 

B2

 

 

PS-1820UL

*COMPATIBLE MODELS: MK-1GD

MK-2MCD

MY-CU

MYW-P1L

MYW-P3L

MYW-P10L

+

+

-

 

 

-

 

VIDEO IN

NOTES:

1.

JA-D is the only compatible door

 

station with this unit.

2.

Video Output is optional. If not

 

used, set 75 Ohm switch to ON

CCTV Camera

75 Ohm, 1V Peak-to-peak (Independently powered)

Remote Activation*

(Optional, only with no JA-D installed)

*Signaling device that provides a Normally Closed momentary contact.

VIDEO OUT

 

 

 

 

Constant video output for

 

 

 

 

CCTV monitor, DVR, etc.

SENSOR

When VIDEO OUT is connected, set

NC

75 Ohm switch to OFF position.

NC

 

 

 

RELAY

 

 

Normally Open contact for

NO

 

 

 

 

remote device activation

NO

 

 

 

 

(i.e. video switcher, DVR, etc.)

 

 

 

 

position.

3. SENSOR input can be used

only if there is no JA-D door

station connected. When used,

the camera will turn on when the

sensor device is activated.

Pg. 1

Image 1
Contents MKW-M Wiring DiagramCompatible Models MK-1GD MK-2MCD MY-CU MYW-P1L MYW-P3L MYW-P10LOperations SpecificationsInstructions FCC Class B Verification