•Private VLAN feature
•IP Multicast VLAN (IPMVLAN)
•Ethernet services:
¬Service VLAN (SVLAN) and Customer VLAN (CVLAN) transparent LAN services
¬Ethernet
¬Service Access Point (SAP) profile identification
•MEF 9 and 14 certified
•UDLD protection
•Up to 16,000 MAC address learning
•Up to 2000 QOS policy rules
•Up to 1000 ACL policy rules
•Up to 4096 VLANs per switch
Power supplies and power consumption
•Supports redundant
•AC supplies: 90 V to 220 V AC
•DC supplies: 36 V to 72 V DC
•Uses internal main power supplies and externalbackup power supplies directly connected to the rear of the unit or remotely mounted
•Backup power suppliesuse a power shelf to hold one
PoE models
•
•Power shelf holds one
•Dynamic power for PoE with
•Dynamic power for PoE with
Specifications
Indicators
•10/100/1000: PoE, link/activity
•SFP: link/activity
•Stacking: link/activity
System LEDs
•Switch ID (indicates the stack ID of the unit in the stack: 1 to 8)
•System (OK) (chassisHW/SW status)
•PWR (primary power supply status)
•PRI (virtual chassis primary)
•BPS (backup power status)
Physical dimensions (WxDxH)
Chassis size (without mounting brackets)
* Contac t for availability .
•Height: 1.73 in. (4.4 cm)
•Width: 17.32 in. (44.0 cm)
•Depth: 10.63 in. (27.0 cm)
•Height: 1.73 in. (4.4 cm)
•Width: 17.32 in. (44.0 cm)
•Depth: 13.0 in.(33.0 cm)
•Height: 1.73 in. (4.4 cm)
•Width: 17.32 in. (44.0 cm)
•Depth: 10.63 in. (27.0 cm)
•Height: 1.73 in. (4.4 cm)
•Width: 17.32 in.(44.0 cm)
•Depth: 10.63 in. (27.0 cm)
Total sizes including power supply shelf for PoE and backup supply
•17.32 x 17.56 x 1.73 in (44.0 x
44.6x 4.4 cm) for 10.63 inch chassis
•17.32 x 19.93 x 1.73 in (44.0 x
50.6x 4.4 cm) for 13.00 inch chassis
Note: All chassis are 19” (48.2 cm) wide with mounting brackets installed
Weight
Chassis
•
•
•
•
PoE without internal power supply
•
•
Power supplies
•
•
•
•
•Power shelf: 1.26 lb (0.57 kg)
EMC
•FCC CRF Title 47 Subpart B (Class A limits. Note: Class A with UTP cables)
•VCCI (Class A limits. Note: Class A with UTP cables)
•AS/NZS 3548 (Class A limits. Note: Class A with UTP cables)
•CE marking for European countries (Class A Note: Class A with UTP cables)
•EN 55022:1995 (EmissionStandard)
•EN
•EN
•EN 55024:1998(ImmunityStandards)
•EN
•EN
•EN
•EN
•EN
•EN
•EN
•IEEE 802.3:
Safety agency certifications
•US UL 60950
•IEC
•EN
•
•
•AS/NZ
•
•
•EN
•CDRH Laser
•China CCC
Environmental requirements
Operating temperature:
• 32° to 113°F (0° to 45°C)
Storage temperature:
•
Humidity (operating and storage):
• 5% to 95%
IEEE standards
•IEEE 802.1D (STP)
•IEEE 802.1p (CoS)
•IEEE 802.1Q (VLANs)
•IEEE
•IEEE 802.1ag (Connectivity Fault Management)
•IEEE 802.1s (MSTP)
•IEEE 802.1w (RSTP)
•IEEE 802.1X (Port Based Network Access Protocol)
•IEEE 802.3i (10BaseT)
•IEEE 802.3u (Fast Ethernet)
•IEEE 802.3x (Flow Control)
•IEEE 802.3z (Gigabit Ethernet)
•IEEE 802.3ab (1000BaseT)
•IEEE 802.3ac (VLAN Tagging)
•IEEE 802.3ad (Link Aggregation)
•IEEE 802.3af
IETF standards
IPV4
•RFC 2003 IP/IP tunneling
•RFC 2784 GRE tunneling
RIP
•RFC 1058 RIP v1
•RFC 1722/1723/2453/1724 RIP v2 & MIB
•RFC 1812/2644 IPv4 Router Requirement
•RFC 2080 RIPng
IP Multicast
•RFC 1112 IGMP v1
•RFC 2236/2933 IGMP v2 & MIB
•RFC 2365 Multicast
•RFC 3376 IGMPv3
IPV6
•RFC 1886 DNS for IPv6
•RFC 2292/2373/2374/2460/2462IPv6
•RFC 2461 NDP
•RFC 2463/2466 ICMP v6 & MIB
•RFC 2452/2454 IPv6 TCP/UDP MIB
•RFC 2464/2553/2893/3493/3513IPv6
•RFC 3056 IPv6 Tunneling
•RFC 3542/3587 IPv6
Manageability
•RFC 854/855 Telnet & Telnet options
•RFC
•RFC 1157/2271 SNMP
•RFC 1212/2737 MIB &
•RFC
•RFC 1215 Conventionfor SNMPTraps
•RFC 1573/2233/2863 Private Interface MIB
•RFC 1643/2665 Ethernet MIB
•RFC
•RFC 2096 IP MIB
•RFC
•RFC 2616 /2854 HTTP & HTML
•RFC 2667 IP Tunneling MIB
•RFC 2668/3636IEEE 802.3MAUMIB
•RFC 2674 VLAN MIB
•RFC 4251 Secure Shell Protocol architecture
•RFC 4252 The Secure Shell (SSH) Authentication Protocol
Security
•RFC 959/2640 FTP
•RFC 1321 MD5
•RFC 2104 HMAC Message Authentication
•RFC 2138/2865/2868/3575/2618 RADIUSAuthentication& Client MIB
•RFC 2139/2866/2867/2620 RADIUS Accounting & Client MIB
•RFC 2228 step
•RFC 2284 PPP EAP
•RFC 2869/2869bisRADIUS Extension
4 Alcat el- Lucent OmniS witch 6400 Data Sheet