Alcatel-Lucent 6400 manual Specifications, Environmental requirements, RFC 2674 Vlan MIB

Page 4

Alcatel-Lucent 5620 SAM support (5620 SAM release 6.1)

Private VLAN feature

IP Multicast VLAN (IPMVLAN)

Ethernet services:

¬Service VLAN (SVLAN) and Customer VLAN (CVLAN) transparent LAN services

¬Ethernet network-to-network interface (NNI) and user network interface (UNI) services

¬Service Access Point (SAP) profile identification

MEF 9 and 14 certified

UDLD protection

Up to 16,000 MAC address learning

Up to 2000 QOS policy rules

Up to 1000 ACL policy rules

Up to 4096 VLANs per switch

Power supplies and power consumption

Supports redundant hot-swappable power supplies

AC supplies: 90 V to 220 V AC

DC supplies: 36 V to 72 V DC

Non-PoE models

Uses internal main power supplies and externalbackup power supplies directly connected to the rear of the unit or remotely mounted

Backup power suppliesuse a power shelf to hold one 6400-BP (AC) or one 6400-BP-D (DC) supply

PoE models

360-W (AC) and 510-W (AC) power supplies only used with PoE models

Power shelf holds one 510-W AC, or two 360-W AC power supplies

Dynamic power for PoE with 360-W power supply: 240 W

Dynamic power for PoE with 510-W power supply: 390 W

Specifications

Indicators

Per-port LEDs

10/100/1000: PoE, link/activity

SFP: link/activity

Stacking: link/activity

System LEDs

Switch ID (indicates the stack ID of the unit in the stack: 1 to 8)

System (OK) (chassisHW/SW status)

PWR (primary power supply status)

PRI (virtual chassis primary)

BPS (backup power status)

Physical dimensions (WxDxH)

Chassis size (without mounting brackets)

* Contac t for availability .

24-port non-PoE and fiber with internal power supply

Height: 1.73 in. (4.4 cm)

Width: 17.32 in. (44.0 cm)

Depth: 10.63 in. (27.0 cm)

48-port non-PoE with internal power supply

Height: 1.73 in. (4.4 cm)

Width: 17.32 in. (44.0 cm)

Depth: 13.0 in.(33.0 cm)

24-port PoE without power shelf

Height: 1.73 in. (4.4 cm)

Width: 17.32 in. (44.0 cm)

Depth: 10.63 in. (27.0 cm)

48-port PoE without power shelf

Height: 1.73 in. (4.4 cm)

Width: 17.32 in.(44.0 cm)

Depth: 10.63 in. (27.0 cm)

Total sizes including power supply shelf for PoE and backup supply

17.32 x 17.56 x 1.73 in (44.0 x

44.6x 4.4 cm) for 10.63 inch chassis

17.32 x 19.93 x 1.73 in (44.0 x

50.6x 4.4 cm) for 13.00 inch chassis

Note: All chassis are 19” (48.2 cm) wide with mounting brackets installed

Weight

Chassis

Non-PoE with internal supply

OS6400-24 9.43 lbs (4.28 kg)

OS6400-48 11.97 lbs (5.43 kg)

OS6400-U24 9.76 lbs (4.43 kg)

OS6400-U24D 9.23 lbs (4.189 kg)

PoE without internal power supply

OS6400-P24 8.97 lb (4.07 kg)

OS6400-P48 9.92 lb (4.50 kg)

Power supplies

OS6400-BP 126W AC: 2.45 lb (1.11 kg)

OS6400-BP-D 120W DC: 2.09 lb (0.95 kg)

OS6400-BP-P 360W AC: 3.22 lb (1.46 kg)

OS6400-BP-PH 510W AC: 5.71 lb (2.59 kg)

Power shelf: 1.26 lb (0.57 kg)

EMC

FCC CRF Title 47 Subpart B (Class A limits. Note: Class A with UTP cables)

VCCI (Class A limits. Note: Class A with UTP cables)

AS/NZS 3548 (Class A limits. Note: Class A with UTP cables)

CE marking for European countries (Class A Note: Class A with UTP cables)

EN 55022:1995 (EmissionStandard)

EN 61000-3-3: 1995

EN 61000-3-2: 2000

EN 55024:1998(ImmunityStandards)

EN 61000-4-2: 1995+A1: 1998

EN 61000-4-3: 1996+A1: 1998

EN 61000-4-4: 1995

EN 61000-4-5: 1995

EN 61000-4-6: 1996

EN 61000-4-8: 1994

EN 61000-4-11: 1994

IEEE 802.3: Hi-Pot Test (2250 VDC on all Ethernet ports)

Safety agency certifications

US UL 60950

IEC 60950-1:2001; all national deviations

EN 60950-1: 2001; all deviations

CAN/CSA-C22.2 No. 60950-1-03

NOM-019 SCFI, Mexico

AS/NZ TS-001 and 60950:2000, Australia

UL-AR, Argentina

UL-GS Mark, Germany

EN 60825-1 Laser,EN60825-2 Laser

CDRH Laser

China CCC

Environmental requirements

Operating temperature:

• 32° to 113°F (0° to 45°C)

Storage temperature:

-40° to 167°F (-40° to 75°C)

Humidity (operating and storage):

• 5% to 95% non-condensing

IEEE standards

IEEE 802.1D (STP)

IEEE 802.1p (CoS)

IEEE 802.1Q (VLANs)

IEEE 802.1adQ-in-Q(VLAN stacking)

IEEE 802.1ag (Connectivity Fault Management)

IEEE 802.1s (MSTP)

IEEE 802.1w (RSTP)

IEEE 802.1X (Port Based Network Access Protocol)

IEEE 802.3i (10BaseT)

IEEE 802.3u (Fast Ethernet)

IEEE 802.3x (Flow Control)

IEEE 802.3z (Gigabit Ethernet)

IEEE 802.3ab (1000BaseT)

IEEE 802.3ac (VLAN Tagging)

IEEE 802.3ad (Link Aggregation)

IEEE 802.3af (Power-over-Ethernet)

IETF standards

IPV4

RFC 2003 IP/IP tunneling

RFC 2784 GRE tunneling

RIP

RFC 1058 RIP v1

RFC 1722/1723/2453/1724 RIP v2 & MIB

RFC 1812/2644 IPv4 Router Requirement

RFC 2080 RIPng

IP Multicast

RFC 1112 IGMP v1

RFC 2236/2933 IGMP v2 & MIB

RFC 2365 Multicast

RFC 3376 IGMPv3

IPV6

RFC 1886 DNS for IPv6

RFC 2292/2373/2374/2460/2462IPv6

RFC 2461 NDP

RFC 2463/2466 ICMP v6 & MIB

RFC 2452/2454 IPv6 TCP/UDP MIB

RFC 2464/2553/2893/3493/3513IPv6

RFC 3056 IPv6 Tunneling

RFC 3542/3587 IPv6

Manageability

RFC 854/855 Telnet & Telnet options

RFC 1155/2578-2580 SMI v1 & SMI v2

RFC 1157/2271 SNMP

RFC 1212/2737 MIB & MIB-II

RFC 1213/2011-2013 SNMP v2 MIB

RFC 1215 Conventionfor SNMPTraps

RFC 1573/2233/2863 Private Interface MIB

RFC 1643/2665 Ethernet MIB

RFC 1901-1908/3416-3418SNMPv2c

RFC 2096 IP MIB

RFC 2570-2576/3411-3415SNMP v3

RFC 2616 /2854 HTTP & HTML

RFC 2667 IP Tunneling MIB

RFC 2668/3636IEEE 802.3MAUMIB

RFC 2674 VLAN MIB

RFC 4251 Secure Shell Protocol architecture

RFC 4252 The Secure Shell (SSH) Authentication Protocol

Security

RFC 959/2640 FTP

RFC 1321 MD5

RFC 2104 HMAC Message Authentication

RFC 2138/2865/2868/3575/2618 RADIUSAuthentication& Client MIB

RFC 2139/2866/2867/2620 RADIUS Accounting & Client MIB

RFC 2228 step

RFC 2284 PPP EAP

RFC 2869/2869bisRADIUS Extension

4 Alcat el- Lucent OmniS witch 6400 Data Sheet

Image 4
Contents Key benefits Stackable Giga BIT LAN SW I TCH FA MIL YAvailability and performance Key features Key benefits CompliancyFeatures Product specificationsEnvironmental requirements SpecificationsRFC 2674 Vlan MIB Dhcp NTPORD TionOr DER Forma Tion SFP-100-LC-MM