Routing protocols
•OSPF
¬RFC 1370 Applicability Statement for OSPF
¬RFC 1587 OSPF NSSA Option
¬RFC 1765 OSFP Overflow Graceful Handling
¬RFC 2328 OSPFv2.0 Protocol
¬RFC 2370 Opaque LSA Option
¬RFC 3101 OSPF NSSA Option
¬RFC 3630 OSPF Traffic Engineering
•Routing Information Protocol (RIP)
¬RFC 1058 RIP Version 1.0
¬RFC 2082 RIP Version 2.0
¬RFC 2453 RIPv2.0 MD5 Authentication
•MPLS
¬RFC 2702 Requirements for Traffic Engineering over MPLS
Table 2. Ordering information
¬RFC 3031 MPLS Architecture
¬RFC 3032 MPLS Label Stack Encoding
¬RFC 3063 MPLS Loop Prevention Mechanism
¬RFC 4090 MPLS Fast Reroute - Facility Backup Method
¬RFC 4447 Pseudowire Setup and Maintenance Using the Label Distribution Protocol (LDP) FEC 128 Support
¬RFC 4448 Encapsulation Meth- ods for Transport of Ethernet over MPLS Networks
•LDP
¬RFC 3036 LDP Specification
¬RFC 3037 LDP Applicability
•RSVP-TE
¬RFC 2430 A Provider Architec- ture for DiffServ and TE
¬RFC 3209 Extensions to RSVP for LSP Tunnels
¬RFC 3210 Applicability State- ment for Extensions to RSVP for LSP Tunnels
•VPLS
¬RFC 4762 Virtual Private LAN Service (VPLS) using Label Distribution Protocol (LDP) Signaling
•Ethernet Pseudowire
¬IETF draft as defined in draft-
•LSP Ping
¬
¬
•
¬Draft-ietf-bfd-base-05
¬
•Terminal Access Concentrator Access Control Server Plus (TACACS+)
¬IEFT draft as defined in draft-
•SSH
¬IETF draft of SSH Authentication Protocol
¬IETF draft of SSH Connection Protocol
¬IETF draft of SSH Transport Protocol
•RADIUS
¬RFC 2865 Remote Authentication Dial In User Service
¬RFC 2866 RADIUS Accounting
Ordering Code | Item Name | description | |
3HE03250AA | 7250 SAS ESA with software | • | 7250 SAS chassis with 2 SFP GigE uplink ports supporting enhanced services with 2 SFP GigE, |
|
|
| 12 SFP |
|
|
| contact inputs through a |
|
| • Optical ports require SFPs | |
|
| • Power supplies are not included; up to 2 can be installed | |
|
| • Software includes support for enhanced MPLS, | |
|
|
|
|
3HE01189AA | 7250 SAS ES with software | • | 7250 SAS chassis with 2 SFP GigE uplink ports supporting enhanced services, with 2 SFP GigE, |
|
|
| 12 SFP |
|
| • Optical ports require SFPs | |
|
| • Power supplies are not included; up to 2 can be installed | |
|
| • Software includes support for enhanced MPLS, | |
|
|
|
|
3HE01190AA | CES Access Module | • | Access module with |
|
| • Connector | |
|
| • | Distance: 200 m |
|
| • | TCXO variant |
|
| • Up to 2 modules can be installed per chassis | |
|
|
|
|
3HE01544AA | High Performance CES Access Module | • | Access module with |
|
| • Connector | |
|
| • | Distance: 200 m |
|
| • High Performance Clock Recovery (HPCR) with OCXO variant | |
|
| • Up to 2 modules can be installed per chassis | |
|
|
|
|
3HE01191AA | • | ||
|
|
|
|
3HE01192AA | • | 110 V to 220 V AC power supply (one is required; a second is required for optional redundancy) | |
|
|
|
|
3HE00062AA | PBA GigE TX SFP Copper Module | • | |
|
| • | Cat5 |
|
| • | |
|
|
|
|
5 |