Quick Start Guide
Mio Modero DMS Conduit Box
Overview
For more detailed installation, configuration, programming, and operating instructions, refer to the Mio Modero DMS & Mio Modero DMS Pinnacle instruction manual available
Mio Modero DMS Conduit Box (FG039-11) Specifications
Dimensions (HWD) | 6.25 (158.8 mm) x 3.08 (78.3 mm) x 3.50 (88.9 mm) |
|
|
Weight | • Conduit box |
| • Magnetic Post Housing |
|
|
Included | • 4 screws, |
Accessories: | • 1 ground screw, |
| • Mounting template |
|
|
Other AMX | • Mio Modero DMS |
Equipment: | • Mio Modero DMS Pinnacle |
| xx indicates color |
|
|
Installation
It is recommended that you cutout the surface slightly smaller than what is outlined in the installation drawings so that you can make any necessary cutout adjustments.
Before you begin, if you are using the
Note: The device and conduit box must have an Earth ground.
If assembled, pull the Mio Modero DMS from the conduit box.
Rough-in Installation of the Conduit Box
1.Remove the tabs for the expansion clip installation from the conduit box by bending back and forth with pliers. See FIG. 1.
2.Use screws through the
3.Run 12V or CAT5/6 cable and an Earth ground wire into the conduit box. Locations to run power wiring into the conduit box are shown in FIG. 1.
|
| Expansion clip |
Keyhole CAT5/6 | installation tabs | |
installation tabs | and 12V access |
|
Earth ground point
Expansion Clip Installation of the Conduit Box
The expansion clip installation method can be used for podium or other flat surface installations.
1.Cut out the surface for the Mio Modero DMS conduit box using the dimensions shown in FIG. 2. A template is included to help you determine dimensions.
Notches are only required for expansion clip installations
FIG. 2 Mio Modero DMS Cutout Installation Dimensions
2.Remove the tabs for the
3.Thread the CAT5/CAT6, the Earth ground wire and, if necessary, the power cables through one of the provided breakaway access points on the conduit box. Leave enough slack in the wiring to accommodate any
4.Thread the 2 drywall screws through the 2 locations center on both top and bottom of the conduit box (FIG. 1) and then through the expansion clips.
5.Insert the conduit box and expansion clips into the cutout until the rim of the conduit box is flush against the wall.
6.Tighten the 2 drywall clip sets (screws and clips) until the conduit box is flush against the wall.
7.Insert the provided cardboard paint shield into the conduit box if the Mio Modero DMS will not be installed at this time.
Installing the Conduit Box without the Use of Tabs
A brick and mortar installation environment is a great example where no tabs are required.
1.Remove both the tabs for the
2.Thread the CAT5/CAT6, the Earth ground wire and, if necessary, the power cables through one of the provided breakaway access points on the conduit box. Leave enough slack in the wiring to accommodate any
3.Insert the provided cardboard paint shield into the conduit box.
4.While conducting this installation, confirm nothing gets into the conduit box, i.e., mortar.
FIG. 1 Mio Modero DMS Conduit Box
4.Insert the cardboard paint shield into the conduit box if the Mio Modero DMS will not be installed at this time.