AMX NXC-I/O10 Pinouts, Signals, and I/O Mode Functions, +12V Mode default and Open Mode settings

Page 2

Pinouts, Signals, and I/O Mode Functions:

NXC-I/O10 Pinouts, Signals, and I/O Mode Functions

Pin

Signal

SW mode Functions

VO mode functions

 

 

 

 

1

Common

Signal ground

Common #1

 

 

 

 

2

I/O #1

Input #1

Input #1

 

 

 

 

3

Common

Signal ground

Common #2

 

 

 

 

4

I/O #2

Input #2

Input #2

 

 

 

 

5

Common

Signal ground

Common #3

 

 

 

 

6

I/O #3

Input #3

Input #3

 

 

 

 

7

Common

Signal ground

Common #4

 

 

 

 

8

I/O #4

Input #4

Input #4

 

 

 

 

9

Common

Signal ground

Common #5

 

 

 

 

10

I/O #5

Input #5

Input #5

 

 

 

 

11

Common

Signal ground

Common #6

 

 

 

 

12

I/O #6

Input #6

Input #6

 

 

 

 

13

Common

Signal ground

Common #7

 

 

 

 

14

I/O #7

Input #7

Input #7

 

 

 

 

15

Common

Signal ground

Common #8

 

 

 

 

16

I/O #8

Input #8

Input #8

 

 

 

 

17

Common

Signal ground

Common #9

 

 

 

 

18

I/O #9

Input #9

Input #9

 

 

 

 

19

Common

Signal ground

Common #10

 

 

 

 

20

I/O #10

Input #10

Input #10

 

 

 

 

Setting the Voltage Clamp Jumper (+12V or Open):

Set the V-Clamp jumper (J31) to +12V (default) to clamp any voltage connected to I/O ports 1-10 to 12 V. Set to OPEN for connections that will draw more than 12 V. Remember, the +12V and OPEN settings are only enabled when the I/O ports are set to SW mode.

+12V Mode (default) and Open Mode settings

+12V mode setting (default)

Open mode setting

FIG. 4 V- Clamp jumper (J31) settings

Use the default setting for all loads that require less than 12V.

When this jumper is set to Open, and an I/O port is used as an output; the I/O port is rated at 85mA @ 28VDC.

Important! When this jumper is set to Open, it is the technician's responsibility to clamp the external source relay anytime the voltage exceeds 12 V.

The source relay should always be clamped, even if the voltage exceeds 12 V.

Contact the relay manufacturer to determine the size of the clamp diode to place on the source relay.

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

93-2021

REV: C

 

12/07

©2007 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.

AMX reserves the right to alter specifications without notice at any time.

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com

Image 2
Contents NXC-I/O10 FG 2021 Specifications Setting the Switch/Voltage Mode JumpersNXC-I/O10 Specifications NXC-I/O10 Channel AssignmentsNXC-I/O10 Pinouts, Signals, and I/O Mode Functions Pinouts, Signals, and I/O Mode FunctionsSetting the Voltage Clamp Jumper +12V or Open +12V Mode default and Open Mode settings