Installation Sheet
RDA-CKM Dual Choke Module
The
Mounting points
Line In (hot) | |
Load out | connections |
Caution
•All Class 1 wiring must be connected to proper terminals.
•All control wiring must be connected to proper terminals.
•Disconnect power while installing or connecting the unit.
•Keep top and bottom air vents clear at all times.
•Test loads for shorts before connecting.
•Use
•Use
•Run all
•Each dimming circuit must have a separate neutral connection.
•All electrical ratings are for continuous duty.
•For indoor use only.
•AC lighting loads only.
350 µS Choke
Mounting points
FIG. 1 RDA-CKM
RDA-CKM UL and C-UL Ratings:
Input:
•120 VAC, 50/60 Hz, 2400 W
•
Specifications:
•Dimensions (HW): 10.0" x 2.75" (254.00 mm x 69.85 mm)
•Use wires rated at 75°C (167°F)
•Torque terminals to 7
•Max. wire size: 10 AWG (4 mm²)
•Wire stripping length: 0.28" (7 mm)
•Weight: 6.5 lbs (2.95 kg)
•BTU/hr: 300
Suggested Loads:
•Incandescent
•
•Neon,