Special
Order
Products
KBW-M
Video Modulator for the KB Series Color Video System
- INSTRUCTIONS -
The
Camera | |
Output to | input |
| |
|
Input from Motion
Detector
KBW-M TERMINAL DEFINITIONS:
BNC Connector: Coax input from CCTV camera
A1 | |
A2 | |
MD | Input from motion detector |
MD | (with normally open contacts) |
WIRING DIAGRAM: KBW-M Modulator for Standard CCTV camera
|
| |||
A1 |
|
| 1A1 | |
A2 |
|
| 1A2 | |
|
|
|
| |
| A1 |
| 2A1 | |
| A2 |
| 2A2 | |
|
| |||
|
|
|
| |
|
| A1 | 3A1 | |
|
| A2 | 3A2 | |
CCTV Camera |
| |||
|
|
| ||
75 Ohm, 1V |
|
|
| |
(Independently powered) | BNC |
|
| |
|
|
| B1 | |
|
| Cnctr |
| |
| Motion Detector* |
| B2 | |
|
|
| ||
|
| MD | + | |
|
| + | ||
|
| MD | - | |
|
| - | ||
|
|
|
|
(Optional)
NOTES:
1.In this system example, the CCTV camera is on input #3. Cameras are viewed by pressing the MONITOR button (on any monitor.) Press once to turn on camera 1
2.OPTIONAL: An input for a motion detector is provided to activate the CCTV camera. The Monitor will turn on and a chime will be heard. The monitor will stay on for approximately 30 seconds.
* Or any signaling | Motion Detectors with N/O Contacts: |
|
device that provides a | Detection Systems DS720I |
|
normally open | Pulnix 6612 |
|
momentary dry closure. | Intellisense 8140S |
|
| Ademco 1998PI |
|
| Sentrol AP750 | Pg. 1 |
|
|