Ericsson LBI-38505A manual Squelch Checks

Page 10

 

LBI-38505

TROUBLESHOOTING PROCEDURES

LBI-38505

 

 

 

 

 

 

SYMPTOM CHECKS Con’t.

 

 

 

 

 

 

 

SYMPTOM

 

PROCEDURE

 

 

 

 

 

 

 

 

 

 

 

 

IMPROPER SQUELCH OPERATION

 

∙ Check voltages on Schematic Diagram.

 

 

 

 

∙ Make gain and waveform checks with noise.

 

 

 

 

∙ Make gain and waveform checks with 6 kHz signal.

 

 

 

 

∙ Check discrete components in the squelch circuit.

 

 

 

 

∙ Replace IC circuit U603.

 

 

 

 

 

 

 

LOW OR DISTORTED AUDIO

 

∙ Check voltages on Schematic Diagram.

 

 

 

 

∙ Make gain and waveform checks.

 

 

 

 

∙ Check receiver alignment and FM -DET output.

 

 

 

 

∙ Check Q601, Q602, Q605 and other discrete components.

 

 

 

 

 

 

SQUELCH CHECKS

 

 

 

 

 

 

SQUELCHED

UNSQUELCHED

 

 

 

 

 

 

 

 

 

NOISE SQ OUTPUT

U605-2

0.2 VDC

9.9V

 

 

 

 

 

 

 

 

 

 

 

 

CAS

U605-1

0.1 VDC

9.9V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.2 VDC

9.9V

 

RX MUTE

U605-14

 

 

 

 

 

 

 

 

 

 

 

 

RUS

U605-13

0.2 VDC

4.9V

 

 

 

 

 

 

 

 

 

 

 

 

SQ DISABLE SW. INPUT

U606-1

0.2 VDC

9.9V

 

 

 

 

 

 

 

 

 

 

 

 

AUDIO GATE SW. CONTROL

U606-11

0.2 VDC

9.9V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If External Decoder is used (CG, DCG, Type 99, etc.), RX Mute will remain low (regardless of noise squelch output), until proper response is decoded. RX Mute = Noise Sq Output∙ Decoder Output.

In above cases, Sq Disable is assumed high (9.9V). If Sq Disable is grounded, U606-10 = 0.2 Vdc, U606-11 = 9.9 Vdc and Unit is unsquelched for all conditions.

9

Image 10
Contents Table of Contents MastrSpecifications Table of ContentsDisassembly MaintenanceDescription Modification Instructions High Side InjectionFront END Alignment Equipment RequiredIcom Frequency Adjustment Direct Measurement in the Injection ChainAlignment Procedures Complete Receiver AlignmentTest Procedures Test ProceduresPreliminary Adjustments Step Audio Power Output and Distortion Test ProcedureQuick Checks Test Procedures Troubleshooting ProceduresSymptom Checks Step Usable SensitivitySquelch Checks MHz Mastr II Receiver Troubleshooting Procedures