1.Read these safety instructions carefully.

2.Keep this User©s Manual for later reference.

3.Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning.

4.For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible.

5.Keep this equipment away from humidity.

6.Put this equipment on a reliable surface during installation. Dropping it or letting it fall may cause damage.

7.The openings on the enclosure are for air convection. Protect the equipment from overheating. DO NOT COVER THE OPENINGS.

8.Make sure the voltage of the power source is correct before connecting the equipment to the power outlet.

9.Position the power cord so that people cannot step on it. Do not place anything over the power cord.

10.All cautions and warnings on the equipment should be noted.

11.If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage.

12.Never pour any liquid into an opening. This may cause fire or electrical shock.

13.Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel.

14.If one of the following situations arises, get the equipment checked by service personnel:

a.The power cord or plug is damaged.

b.Liquid has penetrated into the equipment.

c.The equipment has been exposed to moisture.

d.The equipment does not work well, or you cannot get it to work according to the user©s manual.

e.The equipment has been dropped and damaged. f. The equipment has obvious signs of breakage.

15.DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW -40 ￿ (-40￿) OR ABOVE 85 ￿ (185 ￿ ). THIS

COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT.

v

Image 5
Contents Industrial 5-port Unmanaged Ethernet switch with 2-port 100FX Industrial 5-port Unmanaged Ethernet switch with 1-port 100FXEKI-2525M EKI-2526MAcknowledgements CopyrightIntel and Pentium are trademarks of Intel Corporation 1st EditionProduct Warranty 2 years Technical Support and Assistance Declaration of Conformity CEFCC Class A Safety Instructions Safety Precaution - Static Electricity Appendix A Pin Assignment & Wiring ContentsChapter Installationviii Overview Introduction Features Specifications Packing List Safety PrecautionSections include CHAPTEREKI-2525M & 2526M User Manual-V2.1-051507 Chapter 1 Overview1.1 Introduction Chapter1 1.2 FeaturesPower 1.3 SpecificationCommunications InterfaceSafety CertificationsOperating Humidity Storage Temperatureon the power supply input 1.5 Safety Precaution1.4 Packing List Power Connection InstallationLED Indicators Dimensions Mounting Network Connection Table 2.1 EKI-2525M/2526M LED Definition Chapter 2 Installation2.1 LED Indicators Chapter2 2.2 Dimensions units mmFigure 2.1 Front View of EKI-2525M/2526M Figure 2.2 Side View of EKI-2525M/2526M Figure 2.3 Rear View of EKI-2525M/2526M Figure 2.4 Top View of EKI-2525M/2526M Please refer to page 17 for pin assignment of power connectorFigure 2.5 Combine the Metal Mounting Kit 2.3 Mounting2.3.1 Wall mounting 2.3.2 DIN-rail Mounting Figure 2.6 Installation to DIN-rail StepFigure 2.7 Installation to DIN-rail Step Figure 2.8 Pin Assignment of the Power Connector 2.4 Network ConnectionFigure 2.9 Pin Assignment of the Power Connector 2.5 Power ConnectionEKI-2525M & 2526M User Manual-V2.1-051507 Troubleshooting 1. Power Input Chapter 3 Troubleshooting3. Diagnosing LED Indicators 2. CableAPPENDIX Pin Assignment & WiringFigure A.2 EIA/TIA-568A It is suggested to adopt ELA/TIA as the wiring of the RJ-45Figure A.1 RJ-45 Pin Assignment Figure A.2 EIA/TIA-568B