ADTX ZRW113 Specifications, Interoperability with Z-WAVE Devices, SUC Support

Page 4

SUC Support

There must be a Static Update Controller in your Z-Wave system for this feature to work. The Static Controller can act as a gateway in the system, since other nodes always know its position (not moved after addition to the network. The “always listening” advantage of the Static Controller is that other nodes can transmit information frames to it whenever needed.

You can assign an “SUC Route” to the ZRW113. Refer to your controller’s instructions on how to do this (if it supports it). Assigning an SUC Route to the ZRW113 allows it to request an update of the Z-Wave devices that are between it and the Z-Wave device to which it was trying to transmit. The ZRW113 will only request an update when a transmission fails.

SPECIFICATIONS

Power:

120 VAC, 60 Hz

Signal (Frequency):

908.42 MHz

Maximum Load - Isolated Contacts: 20 amps (5440 watts) maximum, 277 VAC

 

Motor: 1 H.P. maximum, 120/240 VAC

 

Incandescent: TV8 (Tungsten), 120 VAC, 960W maximum

Range:

Up to 100 feet line of sight between the Wireless Controller and /or the closest HomePro

 

Receiver Module

INTEROPERABILITY WITH Z-WAVE™ DEVICES

A Z-Wave™ network can integrate devices of various classes, and these devices can be made by different manufacturers, just as the ZRW113 can be incorporated into existing Z-Wave™ networks.

The top or bottom of the paddle switch on the ZRW113 can be used to carry out inclusion (adding to the network by adding to a group), association (operate simultaneously with other nodes), exclusion (remove from a group) or reset (remove from the network). Controllers can be replicated in order to provide operation from various locations.

WARRANTY

For warranty and general product information visit our web site at www.act-solutions.com

ABOUT ZRW113’S CERTIFICATION

The ZRW113 is certified to comply with applicable FCC and IC rules and regulations governing RF and EMI emissions.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

FCC NOTICE

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

-Increase the separation between the equipment and receiver.

-Consult the dealer or an experienced radio/TV technician for help.

IC NOTICE

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interfer- ence that may cause undesired operation of the device.

Z-Wave ZRW 113 Instructions, Series 200, Release 2.2

0766-01

HomePro

P/D 011008

4

by ADVANCED CONTROL TECHNOLOGIES, INC.

Image 4
Contents ZRW113 Wall Mounted Switch InstallationRemote Control Auxiliary SwitchLED indication Configuration ZRW113 supports the Association commandZRW113 supports the Configuration command AssociationSpecifications Warranty About ZRW113’S CertificationInteroperability with Z-WAVE Devices SUC Support