ADC Circuit Breaker Panel With Reset Switch Accessories, Unpacking and Inspection, Installation

Page 18

ADCP-80-570 • Issue 2 • March 2006

2 ACCESSORIES

The following accessories for the PowerWorx circuit breaker panel are available:

Cable management bar with mounting screws. Provides cable tie points. Installed at rear of circuit breaker panel by fastening ends of bar to both sides of the panel;

Various sizes of two-hole compression lugs for input power connection.

Lug terminals to connect #10 AWG wire to earth ground.

Circuit breaker designation card kit.

3 UNPACKING AND INSPECTION

Unpack and inspect the various components as follows:

1.Inspect the exterior of the shipping container for evidence of handling that may have damaged the components in the container.

2.Unpack each container while carefully checking the contents for damage and verify with the packing slip.

3.File a claim with the commercial carrier and notify ADC Customer Service if damage is detected or if parts are missing. Save damaged cartons for inspection by the carrier.

4.Refer to Section 8, Customer Information and Assistance at the back of this manual, for repair, replacement, and warranty information.

Save all shipping containers for use if the equipment requires return shipment at a future date.

4 INSTALLATION

The circuit breaker panel must be installed in a central office, equipment room, or restricted access location.

The following guidelines should be used when mounting the circuit breaker panel in a rack:

Mount the circuit breaker panel in the uppermost area of the rack to reduce exposure of the power wiring.

Provide a minimum of 1.75 inches (4.45 cm) of air space (one rack space) between the top of the circuit breaker panel and the next item in the rack for cooling.

Caution: This equipment employs electrical voltage and amperage levels which may be considered an electrical hazard. Care should be exercised to assure that only qualified personnel are allowed to install, operate, maintain, or otherwise come in contact with this equipment when the circuit breaker panel is energized.

Warning: Never install power equipment in a wet location or during a lightning storm. When installing or modifying power lines, disconnect lines at the source before working with uninsulated lines or terminals to prevent electrical shock.

Page 12

© 2006, ADC Telecommunications, Inc.

Image 18
Contents ADCP-80-570 Issue March Trademark Information CopyrightRevision History Disclaimer of LiabilityTable of Contents 2006, ADC Telecommunications, Inc Standard Certification General Safety PrecautionsAbout this Manual AdmonishmentsList of Acronyms Product Functions and Features Product DescriptionPanel Components Circuit Breaker Panel Components Packaged Hardware Packaged HardwarePower Buses Circuit Breaker Panel Block DiagramInput Voltage Input ConnectorsOutput Connectors Output VoltagePower-on Indicators Chassis Ground ConnectionsCircuit Breakers Alarm Connections Breaker Alarm IndicatorsAlarm Operation Reset SwitchVoltage Designation Label Material and FinishCooling Protective Covers MountingSpecifications PhysicalDimensions TorqueAccessories InstallationUnpacking and Inspection Installation Tools Required Pre-Installation TestingMaterials Required Test 1 Input Battery to Input Return Test 3 Input Return to Output Return Cable Management Bar Optional Accessory Mounting Panel on RackRepositioning the Mounting Brackets Optional Installing Designation Cards Installing Voltage Designation LabelInstalling Ground Wires Connecting Alarms Installing Ground WiresConnecting Output Alarm TerminalsConnecting Input Connecting Power OutputInstalling Input Power Installing Protective Covers Installing Protective CoversTesting Testing Power Indicators and Connection PolarityTesting Alarm Contacts Normal State Connecting New Equipment OperationPerforming a Routine Inspection Using the Reset SwitchMaintenance Replacing a Circuit BreakerReleasing the Circuit Breaker Lock Tab Circuit Breaker Customer Information and Assistance Phone A. or CanadaADCP-80-570 Issue 2 March Appendix a Allowable Ampacities of Insulated Conductors Correction Factors

Circuit Breaker Panel With Reset Switch specifications

An ADC Circuit Breaker Panel with Reset Switch is an essential component in modern electrical systems, designed to enhance safety and efficiency in power distribution. This panel serves as a protective mechanism, safeguarding electrical circuits from overloads and short circuits, while the reset switch provides a user-friendly means of restoring functionality without the need for complete disconnection.

One of the primary features of the ADC Circuit Breaker Panel is its advanced circuit protection technology. Utilizing either thermal or magnetic mechanisms, these breakers can detect abnormalities in current flow and automatically interrupt the circuit. Thermal breakers respond to excessive heat generated by an overload, while magnetic breakers react quickly to short circuits, ensuring minimal damage to both the electrical system and connected appliances.

Another important characteristic of this panel is its modular design. The customizable layout allows for the integration of various circuit breakers based on specific requirements, accommodating different circuit voltages and capacities. This adaptability makes the ADC Circuit Breaker Panel suitable for a wide range of applications, from residential homes to commercial buildings and industrial settings.

Energy efficiency is a key concern in modern electrical design, and the ADC panel plays a significant role in this aspect. With features like smart monitoring systems, users can keep track of power consumption, helping to identify inefficiencies and reduce energy waste. This promotes sustainable practices and can lead to significant cost savings over time.

Incorporating modern technologies, these panels often come equipped with digital displays and connectivity options. This enables real-time monitoring and alerts for any irregularities, enhancing overall system reliability. Some models even support remote access, allowing users to manage and monitor their electrical systems from anywhere, further increasing convenience and safety.

Moreover, safety is paramount in the design of ADC Circuit Breaker Panels. The inclusion of a reset switch means that instead of replacing blown fuses or constantly resetting breakers manually, users can simply press the switch to restore power. This feature not only saves time but also reduces the risk of accidental electrical mishaps.

In summary, the ADC Circuit Breaker Panel with Reset Switch blends advanced technology, adaptability, and enhanced safety features into a compact design. With its capacity for efficient energy management and user-friendly operation, it stands out as a crucial element in the evolution of electrical distribution and protection systems.