CONNECTIONS

All connections are made through the 50-pin amphenol connector on the back panel TA 750/850/1500.

ELECTRICAL CODE COMPLIANCE

MODES OF OPERATION

Note: Signaling states are provisioned through the BCU.

FXS

FXS Loop Start (default)

FXS Ground Start

The Quad FXS and Quad FXO are to be installed in restricted access locations and in equipment with a Type “B” or “E” installation code.

Code Input Output

IC A

TC –X

PC CC

TR-08 Single Party

TR-08 Universal Voice Grade

DPO

Tandem (E & M)

FXO

FXO Loop Start (default)

FXO Ground Start

APPLICATIONS

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by ADTRAN could void the user’s authority to operate this equipment.

Switch

DPT

ATTENUATION LEVELS

0 dB to -9 dB

FXS

Short loop default: -6 dB Transmit, –3 dB Receive

Long loop default: -3 dB Transmit, –3 dB Receive

FXO

Default 0 dB Transmit, 0 dB Receive

Switch

 

 

 

 

 

DS1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data Switch

 

 

 

 

 

 

 

 

 

GR303

 

 

 

DS1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

GR303 Access

 

 

 

 

 

Concentrator

TDM

DCS

IMPEDANCE SETTINGS

FXS

600

900

600 + 2.16 µF (short loop default)

900 + 2.16 µF (long loop default)

 

 

 

FXO

 

 

 

900 + 2.16 µF

 

 

 

WARRANTY

 

 

 

 

 

 

Warranty for Carrier Networks products manufactured by ADTRAN and supplied under

 

 

 

Buyer's order for use in the U.S. is ten (10) years. For a complete copy of ADTRAN's U.S.

 

Router

 

Carrier Networks Equipment Warranty: (877) 457-5007, Document 414.