ADTRAN TRDDS-R warranty L5-5A Issue 1, April Clei Code # D4OIKTU8, General

Page 1

Section 61291021L5-5A

Issue 1, April 1999

CLEI Code # D4OIKTU8 _ _

TRDDS-R

Total Reach® All Rate DDS Termination Unit

For Outside Plant and Customer Premise

Installation and Maintenance

CONTENTS

 

1.

GENERAL

1

2.

OPTIONS

2

3.

INSTALLATION

2

4.

TESTING

4

5.

DEPLOYMENT GUIDELINES

6

6.

WARRANTY AND CUSTOMER SERVICE

7

FIGURES

 

 

Figure 1.

ADTRAN TRDDS-R

1

Figure 2. Total Reach DDS Circuit Diagram

2

Figure 3. TRDDS-R Option Switch

2

Figure 4. Circuit Card Pin Assignments

3

Figure 5. Signal Loss Indication

4

Figure 6. Total Reach Dataport Bidirectional Loopback

 

 

 

Pass-Thru Mode

6

Figure 7. Total Reach Dataport Bidirectional Loopback

 

 

 

Normal Mode

6

TABLES

 

 

Table 1.

Wiring Connections

3

Table 2.

UL/CUL Telecommunications Codes

3

Table 3.

Faceplate Indicators

4

Table 4.

TRDDS-R and Total Reach Dataport Loopback

 

 

 

Interoperability Matrix

4

Table 5.

Latching Loopback Sequences

5

Table 6.

Alternating Loopback Sequences

5

Table 7.

Total Reach Dataport Loopbacks

6

Table 8.

Cable Type and Temperature Loss Data

 

 

 

@ 13.3 kHz

7

Table 9.

TRDDS Insertion Loss Measurements

7

Custom

Telecom

E190349

SW 1

Figure 1. ADTRAN TRDDS-R

NOTE

The TRDDS-R must be used with an appropriate Total Reach dataport unit.

1. GENERAL

This practice provides installation and maintenance procedures for the ADTRAN TRDDS-R Total Reach¨ All Rate DDS Termination Unit. Figure 1 is an illustration of the ADTRAN TRDDS-R Unit.

The ADTRAN TRDDS-R is a span-powered termination unit designed to deliver data rates up to 64 kbps and provide testing functionality. Used in combination with a Total Reach dataport unit, the TRDDS-R converts the two-wire Total Reach signal to the traditional four-wire DDS signal for presentation to the customer.

The TRDDS-R is an auto-rate adaptive digital network interface typically located at the customer premises point-of- demarcation. The TRDDS-R will deliver a standard four- wire DDS signal up to 18 kft beyond the TRDDS-R. Both customer and network interfaces are equipped with outside plant lightning protection. The customer interface is capable of receiving signals attenuated to -45dB at the Nyquist frequency of four-wire AMI DDS. In addition to terminating the two-wire extended range signal, the TRDDS- R functions as a regenerative loopback device supporting Telco-generated testing. The TRDDS-R unit is available in T200 mechanics, and may be optioned for 0 or Ð10 dB output toward the customer. Figure 2 illustrates the Total Reach DDS Circuit Diagram.

Trademarks: Any brand names and product names included in this document are trademarks,

61291021L5-5ASection 61291021L5-5A, Issue 1Page 1 registered trademarks, or trade names of their respective holders.

Image 1
Contents General L5-5A Issue 1, April Clei Code # D4OIKTU8Wiring InstallationOptions 0dB 10dBSignal Meter Display IndicatorsElectrical Code Compliance PinTotal Reach DDS TRDDS-R Loopback Dataports Faceplate IndicatorsBytes Latching Loopback Sequences Number Function Byte CodeAlternating Loopback Sequences Function Received Bytes Network Interface Equipment Latching LoopbackDS0 Total Reach Dataport Loopbacks Total Reach DDS DataportsDeployment Guidelines Warranty and Customer Service