Adder Technology manual X200 module switches, Switches 2

Page 8

X200 module switches

Certain aspects of operation can be affected by the switches on the X200 module.

OFF: Normal operation

ON: Flash upgrade

ON

1

2

 

 

 

3

4

 

 

 

 

 

Determines configuration of hotkeys in conjunction with switch 3

Reserved for future use

Switch 1

OFF: Normal operation.

ON: (Before power is applied) Places the X200 module into flash upgrade mode so that the internal software can be changed. Please see the Flash upgrade section in the ‘Special configuration’ chapter.

Switches 2 and 3

contents

Determines configuration of hotkeys in conjunction with switch 2

ON 1

2

 

 

 

3

4

 

 

 

 

 

Note: When shipped, all switches are set in the OFF positions and this will produce normal operation.

Switches 2 and 3 determine which two keyboard keys (when pressed in unison) are to be designated as ‘hotkeys’. Hotkeys signal to the X200 module that the next key to be pressed is a special configuration command for the module and is not to be passed to the computer system.

2

OFF

 

3

OFF

Hotkeys = CTRL and SHIFT

2

OFF

 

3

ON

Hotkeys = ALT and SHIFT

2 ON

 

3

OFF

Hotkeys = CTRL and ALT

2 ON

 

3

ON

Hotkeys disabled

Switch 4

This switch is reserved for future use.

 special installation  configuration & welcome



Image 8
Contents Adder X200 Extender Contents X200 receivers only for use with CATx switches etc IntroductionX200 model range Extender pair packages X200 + CAMSupplied items What you may additionally needCable length advice Resolution X200 without de-skew X200 with de-skewWhen used with an AdderView CATx switch ConnectionsConnections at each CAM local unit Welcome contents Connections at the X200 remote moduleSwitches 2 X200 module switchesSwitch Selecting and using computers OperationGeneral use Locking and unlocking the systemConfiguration Entering, using and exiting configuration modeTo enter and use configuration mode To exit from configuration modePassword setting Mouse switching controlTo set a password To clear a password and restore factory default settingsHot plugging PS/2-style connections and mouse restoration Microsoft and Logitech -specific mouse settingsWhich restore setting do I use? Video compensation sharpness and brightness To apply remote user video compensationVideo skew adjustment X200AS models only To use skew adjustmentMiscellaneous settings Report X200-series firmware versionPerforming flash upgrades To perform a flash upgradeWhere Vxxx is the upgrade file version number Issues to consider when performing flash upgradesGetting assistance US +1 888 275Warranty Safety informationRadio Frequency Energy European EMC directive 89/336/EECFCC Compliance Statement United States Canadian Department of Communications RFI statementHoe Huat Industrial Building