RuggedCom RSG2200 manual EMI and Environmental Type Tests

Page 5

RuggedSwitchTM RSG2200

9-Port Managed Gigabit Ethernet Switch

EMI and Environmental Type Tests

IEC 61850-3 EMI TYPE TESTS

TEST

Description

 

Test Levels

Severity Levels

IEC 61000-4-2

ESD

 

Enclosure Contact

+/- 8kV

4

 

 

 

 

 

Enclosure Air

+/- 15kV

4

 

 

 

IEC 61000-4-3

Radiated RFI

 

Enclosure ports

20 V/m

x

 

 

 

 

 

 

 

 

 

Signal ports

+/- 4kV @ 2.5kHz

x

 

 

 

 

 

 

 

 

 

D.C. Power ports

+/- 4kV

4

IEC 61000-4-4

Burst (Fast Transient)

 

 

 

 

 

A.C. Power ports

+/- 4kV

4

 

 

 

 

 

 

 

 

 

 

 

 

Earth ground ports 3

+/- 4kV

4

 

 

 

Signal ports

+/- 4kV line-to-earth, +/- 2kV line-to-line

4

 

 

 

 

 

 

IEC 61000-4-5

Surge

 

D.C. Power ports

+/- 2kV line-to-earth, +/- 1kV line-to-line

3

 

 

 

A.C. Power ports

+/- 4kV line-to-earth, +/- 2kV line-to-line

4

 

 

 

 

 

 

 

 

 

Signal ports

10V

3

 

 

 

 

 

 

 

 

 

D.C Power ports

10V

3

IEC 61000-4-6

Induced (Conducted) RFI

 

 

 

 

 

A.C. Power ports

10V

3

 

 

 

 

 

 

 

 

 

 

 

 

Earth ground ports 3

10V

3

IEC 61000-4-8

Magnetic Field

 

Enclosure ports

40 A/m continuous, 1000 A/m for 1 s

N/A

 

 

 

 

 

 

 

 

 

D.C. Power ports

30% for 0.1s, 60% for 0.1s, 100% for 0.05s

N/A

IEC 61000-4-29

 

 

 

 

 

Voltage Dips & Interrupts

 

 

30% for 1 period, 60% for 50 periods

N/A

 

 

 

 

 

 

A.C. Power ports

 

 

IEC 61000-4-11

 

 

100% for 5 periods, 100% for 50 periods 2

N/A

 

 

 

 

 

 

Signal ports

2.5kV common, 1kV diff. mode@1MHz

3

 

 

 

 

 

 

IEC 61000-4-12

Damped Oscillatory

 

D.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

3

 

 

 

 

 

 

 

 

 

A.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

3

IEC 61000-4-16

Mains Frequency Voltage

 

Signal ports

30V Continuous, 300V for 1s

4

 

 

 

 

 

D.C. Power ports

30V Continuous, 300V for 1s

4

 

 

 

IEC 61000-4-17

Ripple on D.C. Power Supply

 

D.C. Power ports

10%

3

 

 

 

 

 

 

 

 

 

Signal ports

2kVac (Fail-Safe Relay output)

N/A

 

 

 

 

 

 

IEC 60255-5

Dielectric Strength

 

D.C. Power ports

2kVac

N/A

 

 

 

A.C. Power ports

2kVac

N/A

 

 

 

 

 

 

 

 

 

Signal ports

5kV (Fail-Safe Relay output)

N/A

 

 

 

 

 

 

IEC 60255-5

H.V. Impulse

 

D.C. Power ports

5kV

N/A

 

 

 

 

 

 

 

 

 

A.C. Power ports

5kV

N/A

 

 

 

 

 

 

IEEE 1613 (C37.90.x) EMI IMMUNITY TYPE TESTS

Test

Description

 

Test Levels

Severity Levels

IEEE C37.90.3

ESD

 

Enclosure Contact

+/- 8kV

N/A

 

 

 

 

 

Enclosure Air

+/- 15kV

N/A

 

 

 

 

 

 

 

 

 

IEEE C37.90.2

Radiated RFI

 

Enclosure ports

35 V/m

N/A

 

 

 

 

 

 

 

 

 

Signal ports

+/- 4kV @ 2.5kHz

N/A

 

 

 

 

 

 

IEEE C37.90.1

Fast Transient

 

D.C. Power ports

+/- 4kV

N/A

 

 

 

 

 

A.C. Power ports

+/- 4kV

N/A

 

 

 

 

 

 

 

 

 

 

 

 

Earth ground ports3

+/- 4kV

N/A

 

 

 

 

 

 

 

 

 

Signal ports

2.5kV common mode @1MHz

N/A

 

 

 

 

 

 

IEEE C37.90.1

Oscillatory

 

D.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

N/A

 

 

 

 

 

 

 

 

 

A.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

N/A

 

 

 

 

 

 

 

 

 

Signal ports

5kV (Fail-Safe Relay output)

N/A

 

 

 

 

 

 

IEEE C37.90

H.V. Impulse

 

D.C. Power ports

5kV

N/A

 

 

 

 

 

 

 

 

 

A.C. Power ports

5kV

N/A

 

 

 

 

 

 

 

 

 

Signal ports

2kVac

N/A

IEEE C37.90

Dielectric Strength

 

 

 

 

 

D.C. Power ports

2kVac

N/A

 

 

 

 

 

 

 

 

 

A.C. Power ports

2kVac

N/A

 

 

 

 

 

 

Environmental Type Tests

Test

Description

 

Test Levels

Severity Levels

IEC 60068-2-1

Cold Temperature

 

Test Ad

-40°C, 16 Hours

N/A

 

 

 

 

 

 

IEC 60068-2-2

Dry Heat

 

Test Bd

+85°C, 16 Hours

N/A

 

 

 

 

 

 

IEC 60068-2-30

Humidity (Damp Heat, Cyclic)

 

Test Db

95% (non-condensing), 55°C , 6

N/A

 

cycles

 

 

 

 

 

 

 

 

 

 

 

IEC 60255-21-1

Vibration

 

Tests Fc

2g @ (10 - 150) Hz

Class 2

 

 

 

 

 

 

IEC 60255-21-2

Shock

 

Tests Ea

30g @ 11mS

Class 2

 

 

 

 

 

 

Notes: 1. Only applicable to functional earth connections separated from the safety earth connection.

2.Class 2 refers to "Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high, ( e.g. shipboard application and for severe transportation conditions")

www.RuggedCom.com

RuggedSwitchTM RSG2200

5

 

 

 

 

 

Image 5
Contents Rugged Operating System Rostm Features Cyber Security FeaturesUniversal Power Supply Options Ethernet PortsEthernet Modules RuggedSwitch RSG2200Rostm Features Port Configuration and Status Port Based Network Access ControlEvent Logging and Alarms Configuration via Ascii Text FileTest EMI and Environmental Type TestsTechnical Specifications Dimensions Mounting Options Order Codes For additional information on our products
Related manuals
Manual 33 pages 52.03 Kb

RSG2200 specifications

The RuggedCom RSG2200 is an advanced, high-performance router designed specifically for mission-critical applications in harsh environments, making it an ideal choice for industries such as transportation, utilities, and telecommunications. This rugged router combines exceptional reliability, robust features, and cutting-edge technology to meet the stringent demands of industrial networks.

One of the RSG2200's main features is its rugged design, which includes a durable enclosure that meets or exceeds IP40 ratings. This ensures protection against dust and moisture, making it suitable for outdoor installations and environments prone to extreme temperatures and vibrations. The device can operate in a temperature range from -40°C to 85°C, ensuring continuous performance even under adverse conditions.

The RSG2200 supports a wide variety of networking protocols, including Ethernet, MPLS, and IP, offering users and organizations the flexibility to implement diverse networking solutions. Additionally, it features multiple Gigabit Ethernet ports that facilitate high-speed data transfer and provide redundancy through various Ethernet redundancy protocols like Rapid Spanning Tree Protocol (RSTP) and Media Redundancy Protocol (MRP).

For enhanced security, the RSG2200 is equipped with advanced firewall capabilities, VPN support, and intrusion detection systems, which are critical for protecting sensitive data and ensuring the integrity of the network. This makes it well-suited for applications requiring secure communications, such as Smart Grid implementations or critical infrastructure monitoring.

Another noteworthy characteristic of the RSG2200 is its modular design, allowing for easy upgrades and expansions to adapt to changing network requirements. Users can customize the router with different port configurations or add specialized modules for additional functionalities, providing long-term investment protection and scalability.

The RuggedCom RSG2200 utilizes Quality of Service (QoS) features, enabling priority traffic handling and bandwidth allocation for critical applications. This ensures that time-sensitive data, such as voice or video communications, receive the bandwidth they need, improving overall network performance.

In summary, the RuggedCom RSG2200 is a robust and feature-rich router designed for industrial applications that require high reliability, performance, and security. Its rugged construction, versatility, and advanced networking capabilities make it an ideal solution for organizations looking to build and maintain reliable, secure networks in challenging environments.