RuggedCom RS940G manual Technical Specifications, Ietf Snmp Mibs

Page 6

RuggedSwitchTM RS940G

8-Port Managed Gigabit Ethernet Switch

Technical Specifications

Power Supply

￿.Power Consumption: 18W Max

￿.24VDC: 9-36 VDC, 0.4A

￿.48VDC: 36-72 VDC, 0.2A

￿.HI Voltage AC/DC: 88-300VDC or 85-264VAC

Critical Alarm Relay

￿.Form-C failsafe contact relay: 1A@30VDC

Physical

￿.Height: 7.4"

￿.Width: 2.6"

￿.Depth: 5.0"

￿.Weight: 2.7lbs

￿.Ingress Protection: IP40 (1mm objects)

￿.Enclosure: 20 AWG galvanized steel enclosure

￿.Mounting: DIN rail or panel mounted

Switch Properties

￿.Switching method: Store & Forward

￿.Switching latency: 7 us

￿.Switching bandwidth: 5.6Gbps

￿.MAC addresses: 8192

￿.MAC address table size: 32kbytes

￿.Priority Queues: 4

￿.Frame buffer memory: 2 Mbit

￿.VLANs: 4094

￿.IGMP multicast groups: 256

￿.Port rate limiting: 128kbps, 256, 512, 4, 8Mbps ￿.No head of line blocking

Approvals

￿.Hazardous Locations: Class 1, Division 2

￿.ISO: Designed and manufactured using a ISO9001: 2000 certified quality program

￿.CE Marking

￿.Emissions: FCC Part 15 (Class A), EN55022 (CISPR22 Class A)

￿.Safety: cCSAus (Compliant with CSA C22.2 No. 60950, UL 60950, EN60950)

￿.Laser Eye Safety (FDA/CDRH): Complies with 21 CFR Chapter1, Subchapter J.

Warranty

￿.5 Years - Applicable to design and manufacturing related product defects.

Network Management

￿.HTTP graphical web-based ￿.SNMP v1, v2c, v3 ￿.Telnet, VT100

￿.Command Line Interface (CLI)

EMI Immunity and Environmental Compliance

￿.IEC 61000-6-2 Industrial (Generic)

￿.IEC 61800-3 Industrial (Variable Speed Drive Systems) ￿.IEC 61850-3 Electric Utility Substations

￿.IEEE 1613 Electric Utility Substations

￿.NEMA TS 2 Traffic Control Equipment (pending)

IEEE Compliance

￿.802.3-10BaseT

￿.802.3u-100BaseTX, 100BaseFX ￿.802.3x-Flow Control ￿.802.3z-1000BaseLX ￿.802.3ab-1000BaseTX ￿.802.3ad-Link Aggregation ￿.802.1d-MAC Bridges ￿.802.1d-Spanning Tree Protocol ￿.802.1p-Class of Service ￿.802.1q-VLAN Tagging ￿.802.1w-Rapid Spanning Tree Protocol

￿.802.1x-Port Based Network Access Control

IETF RFC Compliance

￿.RFC768-UDP

￿.RFC783-TFTP ￿.RFC791-IP ￿.RFC792-ICMP ￿.RFC793-TCP ￿.RFC826-ARP ￿.RFC854-Telnet ￿.RFC894-IP over Ethernet ￿.RFC1112-IGMP v1 ￿.RFC1519-CIDR ￿.RFC1541-DHCP (client) ￿.RFC2030-SNTP ￿.RFC2068-HTTP ￿.RFC2236-IGMP v2 ￿.RFC2284-EAP

￿.RFC2475-Differentiated Services ￿.RFC2865-Radius ￿.RFC3414-SNMPv3-VSM ￿.RFC3415-SNMPv3-VACM

IETF SNMP MIBS

￿.RFC1493-BRIDGE-MIB ￿.RFC1907-SNMPv2-MIB ￿.RFC2012-TCP-MIB ￿.RFC2013-UDP-MIB ￿.RFC2578-SNMPv2-SMI ￿.RFC2579-SNMPv2-TC ￿.RFC2819-RMON-MIB ￿.RFC2863-IF-MIB ￿.draft-ietf-bridge-rstpmib-03-BRIDGE-MIB

￿.draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB ￿.IANAifType-MIB

www.RuggedCom.com

RuggedSwitchTM RS940G

6

 

 

 

 

 

Image 6
Contents Ethernet Ports Cyber Security FeaturesRugged Operating System Rostm Features RuggedRatedTM for Reliability in Harsh EnvironmentsRuggedSwitch RS940G Rostm Features Event Logging and Alarms Port Based Network Access ControlPort Configuration and Status Configuration via Ascii Text FileEMI and Environmental Type Tests ESDTechnical Specifications Ietf Snmp MibsFiber Specifications and Mechanical Drawing LC-SFPOrder Codes PS M P7P8