| ERROR |
|
|
| PCMCIA |
|
|
|
|
|
|
|
LANplex 2500 | Power | Run | Processor | Power | Fan | Temp | Config |
| Inserted |
|
|
|
|
|
|
| |
Green = Active | Inserted |
|
|
|
|
| Port Status | Green = Active | Port Status |
|
|
|
|
|
|
| |
Yellow = Error |
|
|
|
|
|
|
| Yellow = Error |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| Active | Board | Active |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Error | Error | Error |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Board Error |
| 1 |
|
|
| 2 |
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | ||
|
|
|
|
|
| ||||||||||||
|
|
|
|
| 100 Base FX |
| Port Status | Green = Active | Port Status |
|
|
|
|
|
|
| |
|
|
|
|
|
| Yellow = Error |
|
|
|
|
|
|
| ||||
| Board |
|
|
|
|
| Active | Board | Active |
|
|
|
|
|
|
| |
| Error |
|
|
|
|
| Error | Error | Error |
|
|
|
|
|
|
|
| |
option module | Captive screw |
Male SC connector
The LANplex system will automatically reset when a module has been installed with the power on.
If you physically change the configuration of the system after defining an IP interface, the port designated for that interface may no longer be valid. You may have to redefine the interface. For information on defining an IP interface, see the Administration Console User Guide for your LANplex system.
Option Module Module diagnostics run at power up or when replacing a module with the Diagnostics power on. During diagnostics, the module’s port status Error LED is lit
yellow. When diagnostics are successfully completed, the port status Active LED turns green. If the port status Error LED remains yellow, the port is not operational. If the module’s Board Error LED is lit yellow, the module has failed a diagnostic test. To troubleshoot module failures, see Chapter 7: Troubleshooting the System in your Getting Started guide.
3Com Corporation 5400 Bayfront Plaza Santa Clara, California 95052-8154
© 3Com Corporation, 1996. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without permission from 3Com Corporation.
3Com Corporation reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.
3Com Corporation provides this documentation without warranty of any kind, either implied or expressed, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. 3Com may make improvements or changes in the product(s) and/or the program(s) described in this documentation at any time.
3Com and LANplex are registered trademarks of 3Com Corporation. 3Com registered trademarks are registered in the United States, and may or may not be registered in other countries. Other brand and product names may be registered trademarks or trademarks of their respective holders.
Part No.
Published March1996
Revision 01