3Com 3C16751A manual Stacking the Units Together, Rubber Feet, Stacking Clip

Page 9

Stacking the Units Together

The Rubber Feet

The four self-adhesive rubber feet prevent your hub from moving around on your desk. Only stick the feet to the marked areas at each corner of the underside of your hub if you intend to place the unit directly on top of the desk. Do not fix the feet if you are going to use the clip.

The Stacking Clip

The blue stacking clip allows you to stack your OfficeConnect units together neatly and securely.

CAUTION: You can stack up to a maximum of four units. Smaller units must be stacked above larger units.

To fit the clip:

1Place your unit on a flat surface.

2Fit the clip across the top of the unit, as shown in Figure 2 (picture 1), ensuring that the longer sections of the fastening pieces are pointing downwards.

3Align the fastening pieces over the slots found on each side of the unit.

4Push the clip down gently to secure it, ensuring the fastening pieces snap into the slots on the unit.

To fit another unit:

1Rest the second unit on top of the clip and align it with the front of the unit below.

2Press down gently on the unit to secure it onto the clip, ensuring the fastening pieces fit into the slots on the unit below, as shown in Figure 2 (picture 2).

Figure 2 Stacking Your Units Together

1

Fastening

2

 

 

 

Piece

 

 

 

Fastening

 

 

Piece

To remove the clip:

1Remove the top unit together with the clip. If you hook a finger around one of the the fastening pieces and then pull it gently from out of the slot, the clip should come away with the upper unit attached to it.

2Push the clip in the center, so it bends towards the base of the unit, and then separate once the clip is loose.

9

Image 9
Contents OfficeConnect Dual Speed Hub 3Com Corporation 5400 Bayfront Plaza Santa Clara, California Introduction Creating your Network Page Small Network With OfficeConnect Hub IntroductionDual Speed Hub 16-Front Creating Your NetworkPort Status LEDs Network Utilization LEDsUplink/Normal switch Power Adapter socketDual Speed Hub 16-Rear Sixteen 10/100BASE-TX portsWorkstation Connections Before You StartTwisted Pair TP Cables Hub ConnectionsStacking the Units Together Rubber FeetStacking Clip Securing Your Hub Positioning Your HubConnecting Workstations and Other Equipment to Your Hub Connecting Another OfficeConnect HubFast Ethernet 100Mbps Configuration Rules Ethernet 10Mbps Configuration Rules ExampleExample Making the Connection to Another Hub Checking Hub ConnectionsSpot Checks Problem Solving Straight-through Cable/Crossover Cable Networking Terminology Dimensions and Standards Dimensions and Operating ConditionsStandards End Of Life Statement Environmental StatementsRegulated Materials Statement Environmental Statement about the DocumentationImportant Safety Information Wichtige Sicherheitshinweise Consignes Importantes DE Sécurité 3Com Knowledgebase Web Services Online Technical ServicesTechnical Support World Wide Web SiteSupport from 3Com Support from Your Network SupplierCountry Telephone Number Asia, Pacific Rim EuropeEurope, South Africa, and Middle East North America Country Telephone Number Latin AmericaCountry Telephone Number Fax Number Returning Products for Repair3Com Corporation Limited Warranty Warranties Exclusive Disclaimer Electromagnetic Compatibility Wall mounting screw hole guide 142mm 5.6in Part No. DUA 1675-1AAA02 Published June