Adaptec 2268300R How are Disk Drives Identified in SAS?, What are the SAS Connection Options?

Page 93

Appendix A: Introduction to SAS 92

How are Disk Drives Identified in SAS?

In the BIOS and in the management utilities (see Identifying Disk Drives on page 114), disk drives are identified in the following formats:

CNX:DevY = Device Y is attached to Connector X (see Direct-attach Connections below for more information)

BoxX:SlotX = Enclosure X is attached to a disk drive in Slot X (see Backplane Connections below for more information)

ExpX:PhyX = Expander X is attached to Phy X (see SAS Expander Connections below for more information)

where X is the count number.

Note: Devices other than disk drives (CDROM, tape drives, etc...) are listed in order after your system disk drives.

In parallel SCSI, XX is the disk drive’s channel number, YY is the target number, and ZZ is the logical unit number (LUN).

What are the SAS Connection Options?

You can connect end devices to each other through direct cable connections and through backplane connections. When you use one or more expander devices (see page 93), you can create large configurations.

Direct-attach Connections

In a direct-attach connection, SAS or SATA disk drives are connected directly to a SAS card with SAS or mini-SAS cables. One disk drive is attached to one SAS/mini-SAS connector with one SAS/mini-SAS cable (or multiple disk drives are attached to one SAS/mini-SAS connector with one fan-out cable). The figure on page 50 shows an example of direct-attach connections.

The number of direct-attached disk drives is limited to the number of phys supported by the SAS card. (Note that there may be multiple phys within a single connector. See page 93.)

Backplane Connections

In a backplane connection, disk drives and SAS cards are attached to and communicate with each other through a system backplane.

There are two types of backplane connections, passive and active. When connecting to either backplane, it’s important to properly connect your disk drive LEDs in order to identify disk drive conditions. See About Your RAID Controller on page 17 for your RAID controller Activity LED connections and locations.

Once you have connected to a backplane, use Adaptec Storage Manager to manage your disk drives. For more information, refer to the Adaptec Storage Manager User’s Guide on the Adaptec Installation DVD.

.The number of end devices is limited to the number of slots available on the backplane. For example, the Adaptec S50 enclosure, which contains an expander, is a backplane connection that supports up to 12 SAS or SATA disk drives.

Image 93
Contents Serial Attached Scsi RAID Controllers Patents Adaptec by PMC Product Support Limited 3-Year Hardware Warranty Regulatory Compliance Statements Instructions Contents Getting Started Installing the Driver on an Existing Operating System Introduction to SAS Using the Adaptec Flash Utility Safety Information About This Guide How to Find More Information What You Need to Know Before You BeginTerminology Used in this Guide Kit Contents and System Requirements System Requirements Kit ContentsKit Contents and System Requirements About Your RAID Controller Array-level Features Standard RAID Controller FeaturesAdding a Flash Backup Module Adding a Battery Backup ModuleUpgrading the Controller Firmware Advanced Data Protection SuiteAbout the Adaptec RAID Internal mini-SAS connector CN0 Internal mini-SAS CN0 About the Adaptec RAID 5805/5805QCN6 CN2 CN4 CN5 About the Adaptec RAID 5405Z About the Adaptec RAID 5445Z About the Adaptec RAID 5805Z/5805ZQ Aggregate Activity Mode 0 Flash connector About the Adaptec RAID 2405/2405Q I2C, CN0 I2C, CN1 PCIe x8 connector Mounting bracket PCIe x8 connector Connector CN0 CN1 About the Adaptec RAID 6805/6805Q About the Adaptec RAID 6405E About the Adaptec RAID 6805E About the Adaptec RAID 6405T About the Adaptec RAID 6805T/6805TQ Getting Started Choosing a RAID Level Disk Drives Cables Selecting Disk Drives and CablesReplacing the Full-Height Bracket with a Low-Profile Bracket Bracket to the controller board Basic Installation Steps Installation OptionsInstalling with an Operating System Installing on an Existing Operating SystemInstalling the Controller and Disk Drives Installing the Controller Installing a RAID ControllerBefore You Begin Installing the Controller and Disk Drives Supercapacitor module Connector on daughterboard Connecting Drives Directly to the Controller Connecting Disk Drives to Your ControllersConnecting Drives to a System Backplane Connecting Solid State Drives SSDs Next Steps Connecting External DevicesCreating a Bootable Array Setting the Boot Controller Creating an ArrayCreating an Array with the ACU Select Initialize Drives, then press Enter Creating an Array with Adaptec Storage Manager Select Express configuration..., then click NextMaking Your Array Bootable Installing the Driver and an Operating System Creating a Driver Disk Installing with Windows Server Installing with WindowsInstalling with Red Hat Linux 6 or Fedora Linux Installing with Red Hat LinuxInstalling with Debian Linux Installing with SuSE LinuxInsert and mount a USB flash drive Installing with Ubuntu Linux Copy the driver file to the /lib/modules directory Installing with VMware ESX Installing with SolarisInstalling with VMware ESXi Add the VMware ESXi5.0 Software Depots Check if the new driver package is available Installing with FreeBSD Installing the Driver on an Existing Operating System Installing the Driver on an Existing Operating System Installing on Windows Installing on Red Hat, SuSE, or Fedora LinuxInstalling on Windows Server Installing on Ubuntu Linux Installing on Debian LinuxInstalling on VMware Installing on SolarisReboot your computer Installing on FreeBSD Managing Your Storage Space About the Adaptec RAID Controller Configuration Utility Installing Adaptec Storage ManagerAbout Adaptec Storage Manager About the Adaptec Flash Utility About the Adaptec RAID Configuration UtilityWhich Utility Should I Use? Which Utility Should I Use on VMware?Managing Your Storage Space Solving Problems Troubleshooting Checklist Silencing the AlarmMonitoring Disk Drives Status Failed Disk Drive Protected by a Hot Spare Recovering from a Disk Drive FailureFailed Disk Drive Not Protected by a Hot Spare Failure in Multiple Arrays SimultaneouslyDisk Drive Failure in a RAID 0 Array Resetting the ControllerMultiple Failures in the Same Array Failed Drive in maxCache PoolAt the prompt, type drive-letter\afu update /c Introduction to SAS Terminology Used in This Chapter What is SAS?What’s a Phy? How Do SAS Devices Communicate?What’s a SAS Port? What’s a SAS Connector?What’s a SAS Address? What do SAS Cables Look Like?What are the SAS Connection Options? How are Disk Drives Identified in SAS?Direct-attach Connections Backplane ConnectionsSAS Domain SAS Expander ConnectionsHow is SAS Different from Parallel SCSI? 103 Understanding RAIDNon-redundant Arrays RAID Understanding Drive SegmentsRAID 1 Enhanced Arrays RAID 1 ArraysRAID 10 Arrays RAID 5 Arrays RAID 5EE Arrays RAID 50 Arrays RAID 60 Arrays RAID 6 ArraysSelecting the Best RAID Level Using the Adaptec RAID Configuration Utility Introduction to the ARC Utility Using the ACU to Create and Manage ArraysRunning the ARC Utility Navigating the ARC UtilityManaging Existing Arrays Modifying Cache Settings Rescanning Disk Drives Initializing Disk DrivesSecure Erasing Disk Drives Managing Global Hot SparesUsing the ACU to Manage the maxCache Pool Using the ACU to Create and Manage JBODsCreating a New Jbod Managing Existing JBODsModifying Your Controller’s Configuration Using SerialSelect to Modify Controller SettingsOpening SerialSelect Applying Changes and ExitingGeneral Controller Settings Power Management Settings Locating Disk Drives Formatting and Verifying Disk DrivesViewing the Event Log Identifying Disk Drives121 Using the Adaptec Flash UtilityObtaining the Firmware Running the Menu-based AFU Creating the Firmware Update DisksAFU Commands Running the AFU from the Command LineCommand syntax for the Update command is Verify To update a single RAID controller Updating the Flash Using the AFU Command Line145 Controller LED and I2C Connector Quick ReferenceAdaptec RAID 5085 LED Connector Specification J12 I2C Mating Cable Connector Molex 22-43-3030 or equivalent Adaptec RAID 5405/5405Z LED and I2C Connector SpecificationAdaptec RAID 5445/5445Z LED and I2C Connector Specification Activity CN1, Lane J14 Adaptec RAID 5445 only I2C Mating Cable Connector Molex 22-43-3030 or equivalent Adaptec RAID 51245 LED and I2C Connector Specification Activity CN2, Lane Adaptec RAID 51645 LED and I2C Connector Specification Activity CN3, Lane Adaptec RAID 52445 LED and I2C Connector Specification Activity CN4, Lane J25, J26, J27, J28, J29, J30 Adaptec RAID 2405/2405Q LED and I2C Connector Specification Adaptec RAID 2045 LED Connector SpecificationAdaptec RAID 2805 LED and I2C Connector Specification Adaptec RAID 6405/6445 LED and I2C Connector Specification I2C Clock, CN0 Adaptec RAID 6805/6805Q LED and I2C Connector Specification Adaptec RAID 6405E LED Connector Specification Adaptec RAID 6805E LED Connector Specification Adaptec RAID 6405T LED Connector Specification Adaptec RAID 6805T/6805TQ LED Connector Specification Activity CN1, Lane Electrostatic Discharge ESD Safety InformationTechnical Specifications Environmental Specifications DC Power RequirementsCurrent Requirements Index Index Phy Rate setting 113 phys SAS PMC-Sierra, Inc

2268300R specifications

The Adaptec 2268300R is a robust and versatile RAID controller designed for enterprise-level storage needs. Ideal for environments demanding high availability, performance, and data protection, this controller provides organizations with the ability to manage large volumes of data while ensuring reliability.

One of the standout features of the Adaptec 2268300R is its support for various RAID levels, including RAID 0, 1, 5, 6, 10, 50, and 60. This flexibility allows users to choose the configuration that best suits their performance and redundancy requirements. By combining multiple drives into a single logical unit, the controller enhances data throughput and ensures data safety through redundancy.

The controller is built on a SATA and SAS architecture, allowing it to connect directly to both SATA and SAS drives. This broad compatibility is crucial for businesses looking to leverage existing hardware while also scaling their storage infrastructure. The Adaptec 2268300R is equipped with a powerful onboard processor that significantly boosts performance, driving down latency and increasing transaction speeds across connected drives.

Additionally, the Adaptec 2268300R features cache memory with a non-volatile option that enhances data integrity during unexpected power outages. This feature is essential for mission-critical applications where data loss can have severe repercussions. Moreover, the controller supports advanced caching algorithms, optimizing write and read performance to meet the demands of modern applications.

The controller also integrates seamlessly with Adaptec's management suite, providing users with a graphical interface to monitor and manage their storage solutions effectively. The web-based management tool allows administrators to configure RAID settings, monitor disk health, and perform troubleshooting, all from a centralized platform.

Security is another critical aspect of the Adaptec 2268300R. The controller comes equipped with encryption capabilities, enabling users to secure sensitive data at rest—protecting information from unauthorized access. Furthermore, with features like hot-spare drive support and automatic rebuilds, the controller assures continued operation even in the event of a disk failure.

In conclusion, the Adaptec 2268300R is a powerful RAID controller that delivers significant advantages in performance, flexibility, and reliability. With its support for multiple RAID levels, SAS and SATA compatibility, robust caching, and advanced management tools, it stands out as an ideal solution for businesses needing to safeguard and manage their vast data assets efficiently. Whether for enhancing data security or optimizing storage performance, the Adaptec 2268300R remains a sound choice in today’s data-driven landscape.