Video fuzzy
∙Cable too long or wrong type. Use coax cable for high resolution.
Mouse does not move
∙The Vista is turned off after or not connected when CPU was booted or the application using the mouse was run. Exit and
∙PS/2 mouse was not connected when the Vista was powered up or the mouse was disconnected and reconnected. Issue the reset command.
∙Mouse translation set incorrectly.
Video not synchronized or wrong color
∙The cable may be loose, reseat cable.
∙Wrong CPU cable used. If you have a 9515, 9517, 9518, XGA mono or similar monitor you must use special cables or adapters.
∙Cable is defective; try using cable from another CPU if problem goes away cable is defective.
∙Port on the Vista is defective; try using another port on the Vista. If problem goes away port is defective.
Cannot remember the configuration or access password.
∙Call Rose Electronics Technical Support for instructions.