Advanced Battery Management (ABM™) Technology Doubles Battery Service Life

The lead-acid batteries typically used in a UPS are considered viable as long as they can maintain backup times of at least half that of new batteries. The illustration to the right shows that batteries that are constantly trickle charged (as are virtually all other UPS batteries on the market today) reach the end of their useful life in less than half the time of batteries charged using ABM. ABM uses a patented three-stage charging technique that not only doubles battery service life, but also optimizes battery recharge time and provides up to a 60-day advanced notifi- cation of pending end of useful battery life.

E L E C T R I C A L IN P U T

Data based upon tests performed by an independent battery manufacturer.

C O M M U N I C AT I O N S

Voltage

200, 208, 220, 230, & 240 Vac user-selectable;

 

see Model Selection Guide for default settings

Normal Voltage

±20% of nominal voltage without using batteries

Range

 

Extended Voltage

160-288V without using batteries (set via front panel)

Range

 

Frequency

50/60 Hz, ±3 Hz (+5/-3 Hz with extended voltage range)

Connection

Hardwired

Efficiency

96%

E L E C T R I C A L OU T P U T

Power Out

6000 VA/6000 Watts

Voltage Range

±10% of nominal voltage

(online)

 

Voltage Range

±5% of nominal voltage

(on battery)

 

Wave Form

Sine Wave

(on battery)

 

Frequency

Same as input (±0.5% during battery operation)

Connections

Receptacles or hardwired; see Model Selection Guide

Max Current

29A at 208 Vac; 26A at 230 Vac

Output Protection

Resettable circuit breakers

 

 

B AT T E R Y

 

Type

Maintenance-free, sealed, valve-regulated lead-acid

 

(VRLA), (28), 12V 5 AH

Extended Batteries

Maximum of 2 Extended Battery Modules (EBMs)

Backup Time

See Battery Run Times table

Recharge Time

<3 hours to 80% usable capacity

Extended Battery

<10 hours to 80% usable capacity

Recharge Time

 

Serial Ports

(2) Serial communication ports for use with power

 

management software and installable option cards,

 

including ConnectUPS SLC-EM SNMP Adapter and the

 

Port Expander Card

User LEDs

Normal Operation (green), On Battery (yellow),

 

On Bypass (yellow), and Alarm (red)

LCD

Two-line LCD with three button control

LCD Languages

Danish, Dutch, English, French, German, Spanish,

 

Italian, and Japanese

Front Panel Buttons

On, Off, and Alarm Silence/Self Test

Communications

6-foot communication cable included

Cable

 

E N V I R O N M E N TA L AN D SA F E T Y

Operating

10°C to 40°C (25°C for optimal performance)

Temperature

 

Transit Temperature

-20°C to 55°C

Storage Temperature

0°C to 25°C

Humidity (Operation)

20 to 80% (noncondensing)

Humidity

5 to 95%

(Non-operating)

 

Operating Altitude

0 to 10,000 feet (non-operating: 0 to 30,000 feet)

Audible Noise

55 dBA at 1 meter

Safety Markings

UL, CSA, NOM. Models PW5140 6000i and

 

PW5140 6000 HW also CE and VDE

Safety

UL1778; CSA22.2 No.107.1,No.107.2,No.950; CB

Certifications

Bulletin No.86AI; EN50091-1; EN60950;

 

EMKO-TSE207/95; NOM-019-SCFI-1993

EMC Markings

FCC-A; CISPR-A; VCCI

Immunity

IEC 801-2, IEC 801-3, IEC 801-4, IEC 801-5

Surge Suppression

Conforms to IEEE 587B and ANSI C62.41

REPO Port

Meets NEC code 645-11 intent and UL requirements