SUPER MICRO Computer X7DVL-3 Installing DIMMs, Dimm Installation See Figure, Memory Support

Page 26

X7DVL-3/X7DVL-i User's Manual

2-3 Installing DIMMs

Note: Check the Super Micro web site for recommended memory modules.

CAUTION

Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Also note that the memory is interleaved to improve performance (see step 1).

DIMM Installation (See Figure 2-2)

1.Insert the desired number of DIMMs into the memory slots, starting with DIMM #1A. For better memory performance, please install two modules at a time, beginning with DIMM #1A, DIMM #2A, then DIMM #1B, DIMM #2B, and DIMM #1C, DIMM #2C. (See the Memory Installation Table Below.)

2.Insert each DIMM module vertically into its slot. Pay attention to the notch along the bottom of the module to prevent inserting the DIMM module incorrectly.

3.Gently press down on the DIMM module until it snaps into place in the slot. Repeat for all modules (see step 1 above).

Memory Support

The X7DVL-3/X7DVL-i supports up to 16 GB fully buffered (FBD) ECC DDR2 533/667 in 6 DIMMs. Populating DIMM modules with pairs of memory modules of the same size and same type will result in better memory performance.

Note 1: Due to OS limitations, some operating systems may not show more than 4 GB of memory.

Optimized DIMM Population Configurations

Number

 

Bank 1

 

 

Bank 2

 

of DIMMs

 

 

 

 

 

 

 

2 DIMMs

1A

------

------

2A

 

------

------

4 DIMMs

1A

1B

------

2A

 

2B

------

6 DIMMs

1A

1B

1C

2A

 

2B

2C

(Notes: i. DIMM slot# specified: DIMM slot to be

populated; “---“: DIMM slot not to be populated. ii. Both FBD 533 MHz and 667MHz DIMMs are supported; however, we recommend that you use the memory modules of the same speed and of the same type on a motherboard. iii. For memory to work properly, you need to follow the restrictions listed above. )

2-6

Image 26
Contents USER’S Manual Page Conventions Used in the Manual About This ManualManual Organization Table of Contents Table of Contents Bios Checklist OverviewContacting Supermicro HeadquartersX7DVL-3/X7DVL-i Image X7DVL-3/X7DVL-i Motherboard Layout Quick Reference X7DVL-3/X7DVL-i Jumper Description Default SettingLED Indicator Expansion Slots MemoryChipset PC Health MonitoringOnboard I/O Acpi FeaturesDimensions OtherBlock Diagram of the 5000V Chipset FBD DimmXeon Dual Core Processors Xeon Quad Core/Dual Core Processor FeaturesChipset Overview Special Features PC Health MonitoringMain Switch Override Mechanism Acpi FeaturesSlow Blinking LED for Suspend-State Indicator CPU Overheat LED and ControlPower Supply External Modem Ring-OnSuper I/O Page Unpacking PrecautionsStatic-Sensitive Devices Processor and Heatsink Fan Installation Installation of the LGA771 ProcessorPage CEK Heatsink Installation Installation of the HeatsinkTo Un-install the Heatsink Mounting the Motherboard in the Chassis Memory Support Installing DIMMsDimm Installation See Figure Installing and Removing DIMMs Possible System Memory Allocation & AvailabilityControl Panel Connectors/IO Ports Back Panel Connectors/IO PortsJF1 Header Pins Front Control PanelFront Control Panel Pin Definitions NMI Button Power LEDPower LED Pin Definitions JF1 NMI Button Pin Definitions JF1NIC1/NIC2 LED Indicators HDD LEDOH/Fan Fail LED B. PWR Supply Fail Power Fail LEDOverheat/Fan Fail LED OH Reset Button B. PWR Button Reset ButtonPower Button Reset Button Pin Definitions JF1Processor Power Connector Connecting CablesATX Power Connector Required Connection Pin ATX PWRBack Panel USB USB0/1 Universal Serial Bus USBChassis Intrusion Front Panel USB Pin Definitions USB2/3/4/5Fan Headers Power Force On Enable/DisablePower Force On Enable/Disable Jumper Settings JPF Fan Header Pin Definitions Fan1-6Keyboard/Mouse ATX PS/2 Keyboard and PS/2 Mouse PortsSerial Ports PS/2 Keyboard Mouse Port Pin DefinitionsWake-On-Ring Pin Definitions Wake-On-RingWake-On-LAN Wake-On-LAN Pin DefinitionsGlan 1/2 Giga-bit Ethernet Ports Power LED/SpeakerSpeaker Connector GLAN1/2 PWR LED/SpeakerAlarm Reset B. VGA Alarm ResetVGA Connector Alarm ResetSGPIO#0 SGPIO#1 Power SMB I2 C ConnectorSgpio Headers Glan Port1 Enable B. Glan Port2 Enable Jumper SettingsGlan Enable/Disable Glan EnableWatch Dog Jumper Settings JWD Watch Dog Enable/DisableClear Cmos Watch Dog Enable Cmos ClearI2C Bus to PCI Slots VGA Enable/DisableVGA Enabled I2C Bus to PCI slotsPWR Supply Fail B. SAS Enable PWR Supply Failure/PWR Fault Detect JpwfSAS Enable/Disable PWR Supply PWR Fault Jumper SettingsSoftware RAID Jumper Settings Software RAID EnableSoftware RAID Enable Glan LEDs Onboard IndicatorsOnboard Power LED LE1 N k ActivityPost Code LED Indicators LE4, LE5 Cpuvrm Overheat LED Indicators LE2/LE3Status LED D31 D31 Status LEDParallel Printer Port Connector Parallel PortFloppy Floppy ConnectorSimlp Ipmi Slot Simlp SlotIDE Connector IDE#1No Power Troubleshooting ProceduresBefore Power On No VideoMemory Errors Technical Support ProceduresLosing the System’s Setup Configuration Frequently Asked Questions Returning Merchandise for Service Starting the Setup Utility System BiosHow To Change the Configuration Data IntroductionPress the Delete key to enter Setup Running SetupMain Bios Setup System Time Main Bios Setup MenuBios Date System DateType Ultra DMA Mode LBA Mode ControlTransfer Mode Multi-Sector TransfersSerial ATA Sata RAID Enable Native Mode OperationSata Controller Mode Parallel ATAExtended Memory Advanced SetupSystem Memory QuietBoot XBoot FeaturesQuickBoot Mode Post ErrorsCache Base 0-512K XMemory Cache Cache System Bios AreaCache Video Bios Area Cache Base 512K-640KDiscrete Mtrr Allocation PCI Parity Error ForwardingReset Configuration Data Xpci ConfigurationLarge Disk Access Mode Enable MasterLatency Timer Serr Signal ConditionBranch 0 Rank Interleaving High Temperature Dram OperationCrystal Beach Features Branch 0 Rank SparingFrequency Ratio Available when supported by the CPU Clock Spectrum FeatureEnabling Multi-Media Timer Hyperthreading Available when supported by the CPUExecute Disable Bit Available when supported by the CPU Thermal Management 2 Available when supported by the CPUC1 Enhanced Mode Available when supported by the CPU Hardware Prefetcher Available when supported by the CPUKBC Clock Input Intel Eist Support *Available when supported by the CPUXI/O Device Configuration Serial Port aFloppy Disk Controller Parallel PortDMA Channel Xdmi Event LoggingClear All DMI Event Logs ECC Event LoggingMark DMI Events as Read XConsole RedirectionVoltage Monitoring CPU Temperature ThresholdTemperature Monitoring Available if supported by the CPU Fan Speed Control ModesVoltage Monitoring CPU Temperature Threshold *See the Note on Existing Event Log Number System Event LoggingClear System Event Logging Event Log ControlTimer for Loading OS Minutes XSystem Event Log/System Event Log List ModeOS Boot Watch Dog Time Out OptionXRealtime Sensor Data Set Supervisor Password Supervisor Password IsUser Password Is Set User PasswordBoot Priority Order/Excluded from Boot Orders BootPassword on Boot Exit Appendix a Bios Post Error Codes Recoverable Post ErrorsPage Appendix B Installing the Windows OS Page Appendix C Installing Other Software Programs and Drivers Driver/Tool Installation Display ScreenConfiguring Supero Doctor Supero Doctor III Interface Display Screen-II Remote Control

X7DVL-3 specifications

Super Micro Computer, Inc. is a well-respected name in the realm of high-performance computing, offering diverse solutions tailored for various applications. One of the notable offerings from the brand is the Supermicro X7DVL-3 motherboard, designed to provide exceptional performance and reliability for both workstations and servers.

At its core, the X7DVL-3 is built on the Intel 5000X chipset, making it a robust choice for enterprise-level tasks. It supports Intel's dual-core and quad-core Xeon processors, specifically the LGA 771 socket. This design enables users to leverage enhanced processing power, facilitating intensive computational tasks such as virtualization, data analysis, or complex simulations.

One standout feature of the X7DVL-3 is its support for up to 32GB of DDR2 ECC (Error-Correcting Code) memory across four DIMM slots. This memory technology ensures higher reliability and stability, reducing the risk of data corruption—a critical factor for enterprises that require consistent performance and uptime.

In terms of connectivity, the motherboard comes equipped with 6 SATA ports, offering flexible storage options for RAID configurations, enhancing both speed and redundancy. Additionally, the X7DVL-3 features dual Gigabit Ethernet LAN ports, which facilitate high-speed network connectivity and allow for dual network path setups, ensuring seamless communication in network-intensive applications.

The X7DVL-3 is also designed with a high degree of scalability in mind. It includes multiple PCI-E slots, thereby supporting a range of expansion cards, including graphics cards for visualization tasks or additional networking options. This adaptability is crucial for organizations that need to upgrade or modify their systems as their operational demands evolve.

Another notable aspect of the Supermicro X7DVL-3 is its emphasis on efficiency and management. The motherboard is equipped with Supermicro’s IPMI (Intelligent Platform Management Interface) technology, allowing for remote management and monitoring of system health. This feature is particularly valuable in data center environments where managing multiple servers efficiently can lead to significant operational cost reductions.

In summary, the Supermicro X7DVL-3 motherboard stands out with its robust architecture, support for powerful Intel Xeon processors, extensive memory capacity, and advanced connectivity features. Coupled with its emphasis on reliability and manageability, this motherboard represents a solid choice for businesses seeking a dependable solution for their computing needs. Whether in a server configuration or a high-performance workstation, the X7DVL-3 delivers the performance and scalability critical for modern enterprises.